دورية أكاديمية

Impact of an AI software on the diagnostic performance and reading time for the detection of cerebral aneurysms on time of flight MR-angiography.

التفاصيل البيبلوغرافية
العنوان: Impact of an AI software on the diagnostic performance and reading time for the detection of cerebral aneurysms on time of flight MR-angiography.
المؤلفون: Lehnen, Nils C., Schievelkamp, Arndt-Hendrik, Gronemann, Christian, Haase, Robert, Krause, Inga, Gansen, Max, Fleckenstein, Tobias, Dorn, Franziska, Radbruch, Alexander, Paech, Daniel
المصدر: Neuroradiology; Jul2024, Vol. 66 Issue 7, p1153-1160, 8p
مصطلحات موضوعية: ARTIFICIAL intelligence tests, INTRACRANIAL aneurysm diagnosis, INTRACRANIAL aneurysms, READING, WORK, COMPUTER software, COMPUTER-assisted image analysis (Medicine), MAGNETIC resonance angiography, COMPUTER-aided diagnosis, CLINICAL competence, TIME, EXPERIENTIAL learning, SENSITIVITY & specificity (Statistics)
مستخلص: Purpose: To evaluate the impact of an AI-based software trained to detect cerebral aneurysms on TOF-MRA on the diagnostic performance and reading times across readers with varying experience levels. Methods: One hundred eighty-six MRI studies were reviewed by six readers to detect cerebral aneurysms. Initially, readings were assisted by the CNN-based software mdbrain. After 6 weeks, a second reading was conducted without software assistance. The results were compared to the consensus reading of two neuroradiological specialists and sensitivity (lesion and patient level), specificity (patient level), and false positives per case were calculated for the group of all readers, for the subgroup of physicians, and for each individual reader. Also, reading times for each reader were measured. Results: The dataset contained 54 aneurysms. The readers had no experience (three medical students), 2 years experience (resident in neuroradiology), 6 years experience (radiologist), and 12 years (neuroradiologist). Significant improvements of overall specificity and the overall number of false positives per case were observed in the reading with AI support. For the physicians, we found significant improvements of sensitivity on lesion and patient level and false positives per case. Four readers experienced reduced reading times with the software, while two encountered increased times. Conclusion: In the reading with the AI-based software, we observed significant improvements in terms of specificity and false positives per case for the group of all readers and significant improvements of sensitivity and false positives per case for the physicians. Further studies are needed to investigate the effects of the AI-based software in a prospective setting. [ABSTRACT FROM AUTHOR]
Copyright of Neuroradiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:00283940
DOI:10.1007/s00234-024-03351-w