Kidney Segmentation in CT Data Using Hybrid Level-Set Method with Ellipsoidal Shape Constraints

التفاصيل البيبلوغرافية
العنوان: Kidney Segmentation in CT Data Using Hybrid Level-Set Method with Ellipsoidal Shape Constraints
المؤلفون: Skalski Andrzej, Heryan Katarzyna, Jakubowski Jacek, Drewniak Tomasz
المصدر: Metrology and Measurement Systems, Vol 24, Iss 1, Pp 101-112 (2017)
بيانات النشر: Polish Academy of Sciences, 2017.
سنة النشر: 2017
المجموعة: LCC:Technology
مصطلحات موضوعية: Level Set method, kidney, CT data, image segmentation, ellipsoid, Technology
الوصف: With development of medical diagnostic and imaging techniques the sparing surgeries are facilitated. Renal cancer is one of examples. In order to minimize the amount of healthy kidney removed during the treatment procedure, it is essential to design a system that provides three-dimensional visualization prior to the surgery. The information about location of crucial structures (e.g. kidney, renal ureter and arteries) and their mutual spatial arrangement should be delivered to the operator. The introduction of such a system meets both the requirements and expectations of oncological surgeons. In this paper, we present one of the most important steps towards building such a system: a new approach to kidney segmentation from Computed Tomography data. The segmentation is based on the Active Contour Method using the Level Set (LS) framework. During the segmentation process the energy functional describing an image is the subject to minimize. The functional proposed in this paper consists of four terms. In contrast to the original approach containing solely the region and boundary terms, the ellipsoidal shape constraint was also introduced. This additional limitation imposed on evolution of the function prevents from leakage to undesired regions. The proposed methodology was tested on 10 Computed Tomography scans from patients diagnosed with renal cancer. The database contained the results of studies performed in several medical centers and on different devices. The average effectiveness of the proposed solution regarding the Dice Coefficient and average Hausdorff distance was equal to 0.862 and 2.37 mm, respectively. Both the qualitative and quantitative evaluations confirm effectiveness of the proposed solution.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2300-1941
العلاقة: http://www.degruyter.com/view/j/mms.2017.24.issue-1/mms-2017-0006/mms-2017-0006.xml?format=INTTest; https://doaj.org/toc/2300-1941Test
DOI: 10.1515/mms-2017-0006
الوصول الحر: https://doaj.org/article/ef82540f6d134e61aeeeed4c403f6519Test
رقم الانضمام: edsdoj.f82540f6d134e61aeeeed4c403f6519
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:23001941
DOI:10.1515/mms-2017-0006