دورية أكاديمية

Bacterial Detection, Deformation, and Torque Loss on Dental Implants with Different Tapered Connections Compared with External Hexagon Connection after Thermomechanical Cycling

التفاصيل البيبلوغرافية
العنوان: Bacterial Detection, Deformation, and Torque Loss on Dental Implants with Different Tapered Connections Compared with External Hexagon Connection after Thermomechanical Cycling
المؤلفون: Anselmo Agostinho Simionato, Emerson de Souza Santos, Adriana Cláudia Lapria Faria, Cássio do Nascimento, Renata Cristina Silveira Rodrigues, Ricardo Faria Ribeiro
المصدر: Materials, Vol 16, Iss 11, p 3904 (2023)
بيانات النشر: MDPI AG, 2023.
سنة النشر: 2023
المجموعة: LCC:Technology
LCC:Electrical engineering. Electronics. Nuclear engineering
LCC:Engineering (General). Civil engineering (General)
LCC:Microscopy
LCC:Descriptive and experimental mechanics
مصطلحات موضوعية: dental implants, X-ray microtomography, dental implant-abutment design, dental abutments, Technology, Electrical engineering. Electronics. Nuclear engineering, TK1-9971, Engineering (General). Civil engineering (General), TA1-2040, Microscopy, QH201-278.5, Descriptive and experimental mechanics, QC120-168.85
الوصف: The relationship between bacterial infiltration and internal conical Implant-Abutment Interfaces (IAIs) with different conicities still requires investigations that can offer valuable information in the clinical understanding of peri-implant health. The present study aimed to verify the bacterial infiltration of two internal conical connections with an angulation of 11.5° and 16° with the external hexagonal connection as a comparative after thermomechanical cycling using saliva as a contaminant. Test (n = 10) and control (n = 3) groups were set up. Evaluations were made on torque loss, Scanning Electron Microscopy (SEM), and Micro Computerized Tomography (MicroCT) after performing 2 × 106 mechanical cycles (120 N) and 600 thermal cycles (5°–55° C) with 2 mm lateral displacement. The contents of the IAI were collected for microbiological analysis. There was a difference (p < 0.05) in torque loss of the groups tested; groups from the 16° IAI obtained a lower percentage of torque loss. All groups presented contamination and the analysis of the results shows that the microbiological profile of the IAI differs qualitatively from the profile found in the saliva used for contamination. The mechanical loading affects the microbiological profile found in the IAIs (p < 0.05). In conclusion, the IAI environment may favor a microbiological profile different from that of saliva and the thermocycling condition may alter the microbial profile found in the IAI.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1996-1944
العلاقة: https://www.mdpi.com/1996-1944/16/11/3904Test; https://doaj.org/toc/1996-1944Test
DOI: 10.3390/ma16113904
الوصول الحر: https://doaj.org/article/c6e19089076647d1a63e65f915186429Test
رقم الانضمام: edsdoj.6e19089076647d1a63e65f915186429
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:19961944
DOI:10.3390/ma16113904