دورية أكاديمية

Coronary Endothelial Dysfunction Distal to Stent of First-Generation Drug-Eluting Stents.

التفاصيل البيبلوغرافية
العنوان: Coronary Endothelial Dysfunction Distal to Stent of First-Generation Drug-Eluting Stents.
المؤلفون: Mitsutake, Yoshiaki, Ueno, Takafumi, Yokoyama, Shinji, Sasaki, Ken-ichiro, Sugi, Yusuke, Toyama, Yasuyuki, Koiwaya, Hiroshi, Ohtsuka, Masanori, Nakayoshi, Takaharu, Itaya, Naoki, Chibana, Hidetoshi, Kakuma, Tatsuyuki, Imaizumi, Tsutomu
المصدر: JACC: Cardiovascular Interventions; Sep2012, Vol. 5 Issue 9, p966-973, 8p
مصطلحات موضوعية: DRUG-eluting stents, CORONARY disease, ANGINA pectoris, ACETYLCHOLINE, ANGIOSCOPY, ENDOTHELIUM, PATIENTS
مستخلص: Objectives: This study sought to evaluate the relationship between coronary endothelial function and neointimal coverage after drug-eluting stent (DES) implantation. Background: The mechanisms of endothelial dysfunction after DES implantation remain to be fully elucidated. We hypothesized that poor neointimal coverage after DES implantation may be associated with endothelial dysfunction distal to the stent site. Methods: Sixty-six stable angina patients treated with a first-generation DES were enrolled. At 9-month follow-up, coronary endothelial function was evaluated with intracoronary infusion of incremental doses of acetylcholine (10−8, 10−7, and 10−6 mol/l) and nitroglycerin (200 μg). Vascular responses at the segments proximal and distal to the stent site were angiographically and quantitatively measured. At the same time, the degree of neointimal coverage was evaluated using coronary angioscopy and classified into 4 grades: 0 (no coverage) to 3 (full coverage). Results: We divided the subjects into poor-coverage (grades 0 to 1, n = 33) and good-coverage (grades 2 to 3, n = 33) groups. Acetylcholine induced dose-dependent coronary vasoconstrictions in both groups. At the segment distal to the stent, the magnitude of vasoconstriction to acetylcholine in the poor-coverage group was significantly greater than in the good-coverage group (p < 0.001), whereas vasomotor responses proximal to the stent and vasodilation by nitroglycerine were similar between the 2 groups. Conclusions: Coronary endothelial dysfunction distal to the stent was associated with poor neointimal coverage after DES implantation. [ABSTRACT FROM AUTHOR]
Copyright of JACC: Cardiovascular Interventions is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Supplemental Index
الوصف
تدمد:19368798
DOI:10.1016/j.jcin.2012.06.010