دورية أكاديمية

Rethinking Fault Ride-Through Control of DFIG-Based Wind Turbines from New Perspective of Rotor-Port Impedance Characteristics

التفاصيل البيبلوغرافية
العنوان: Rethinking Fault Ride-Through Control of DFIG-Based Wind Turbines from New Perspective of Rotor-Port Impedance Characteristics
المؤلفون: Zhu, Donghai, Wang, Zhen, Hu, Jiabing, Zou, Xudong, Kang, Yong, Guerrero, Josep M.
المصدر: Zhu , D , Wang , Z , Hu , J , Zou , X , Kang , Y & Guerrero , J M 2024 , ' Rethinking Fault Ride-Through Control of DFIG-Based Wind Turbines from New Perspective of Rotor-Port Impedance Characteristics ' , IEEE Transactions on Sustainable Energy , vol. 15 , no. 3 , pp. 2050-2062 . https://doi.org/10.1109/TSTE.2024.3395985Test
سنة النشر: 2024
المجموعة: Aalborg University (AAU): Publications / Aalborg Universitet: Publikationer
مصطلحات موضوعية: Circuit faults, DFIG-based wind turbine, Doubly fed induction generators, essential relations, fault ride through (FRT), Impedance, quantitative evaluation, rotor-side port impedance characteristics (RPIC), Rotors, Stators, Transient analysis, Voltage control
الوصف: To achieve the fault ride through (FRT) operation of DFIG-based wind turbines, various improved control methods have been proposed. However, it is difficult to reveal their essential relations and quantitatively evaluate their performance differences, due to the wide assortment of solving ideas and control structures. To cope with this issue, this paper revisits the FRT control from a new perspective of rotor-port impedance characteristics (RPIC). First, a unified RPIC model of nine typical FRT controls is established and it is found that their RPIC are manifested as the pure inductance, but the inductance values are different in the phase sequence. Subsequently, the influence of RPIC on FRT performance is analyzed and some practical design guidelines for FRT control are given. On this basis, nine typical FRT control methods are quantitatively evaluated and compared in terms of six key performance dimensions. Moreover, the study contributes to the understanding, analysis and redesign of FRT control, and the RPIC perspective features the definite physical meaning and simple. Finally, the analysis is validated by the experiments.
نوع الوثيقة: article in journal/newspaper
اللغة: English
العلاقة: https://vbn.aau.dk/da/publications/f447bb24-b5f8-4cf5-95bd-0eb1a4c7027aTest
DOI: 10.1109/TSTE.2024.3395985
الإتاحة: https://doi.org/10.1109/TSTE.2024.3395985Test
https://vbn.aau.dk/da/publications/f447bb24-b5f8-4cf5-95bd-0eb1a4c7027aTest
http://www.scopus.com/inward/record.url?scp=85192152300&partnerID=8YFLogxKTest
حقوق: info:eu-repo/semantics/restrictedAccess