دورية أكاديمية

Hyperoxemia as a risk factor for ventilator-associated pneumonia.

التفاصيل البيبلوغرافية
العنوان: Hyperoxemia as a risk factor for ventilator-associated pneumonia.
المؤلفون: Six, Sophie, Jaffal, Karim, Ledoux, Geoffrey, Jaillette, Emmanuelle, Wallet, Frédéric, Nseir, Saad
المصدر: Critical Care; 6/22/2016, Vol. 20, p195-195, 1p
مصطلحات موضوعية: APACHE (Disease classification system), ARTIFICIAL respiration, BLOOD transfusion, INTENSIVE care units, MULTIVARIATE analysis, REGRESSION analysis, HYPEROXIA, RETROSPECTIVE studies, VENTILATOR-associated pneumonia, DISEASE complications
مستخلص: Background: Consequences of hyperoxemia, such as acute lung injury, atelectasis, and reduced bacterial clearance, might promote ventilator-associated pneumonia (VAP). The aim of our study was to determine the relationship between hyperoxemia and VAP.Methods: This retrospective observational study was performed in a 30-bed mixed ICU. All patients receiving invasive mechanical ventilation for more than 48 hours were eligible. VAP was defined using clinical, radiologic, and quantitative microbiological criteria. Hyperoxemia was defined as PaO2 > 120 mmHg. All data, except those related to hyperoxemia, were prospectively collected. Risk factors for VAP were determined using univariate and multivariate analysis.Results: VAP was diagnosed in 141 of the 503 enrolled patients (28 %). The incidence rate of VAP was 14.7 per 1000 ventilator days. Hyperoxemia at intensive care unit admission (67 % vs 53 %, OR = 1.8, 95 % CI (1.2, 29), p <0.05) and number of days spent with hyperoxemia were significantly more frequent in patients with VAP, compared with those with no VAP. Multivariate analysis identified number of days spent with hyperoxemia (OR = 1.1, 95 % CI (1.04, 1.2) per day, p = 0.004), simplified acute physiology score (SAPS) II (OR = 1.01, 95 % CI (1.002, 1.024) per point, p < 0 .05), red blood cell transfusion (OR = 1.8, 95 % CI (1.2, 2.7), p = 0.01), and proton pomp inhibitor use (OR = 1.9, 95 % CI (1.03, 1.2), p < 0.05) as independent risk factors for VAP. Other multiple regression models also identified hyperoxemia at ICU admission (OR = 1.89, 95 % CI (1.23, 2.89), p = 0.004), and percentage of days with hyperoxemia (OR = 2.2, 95 % CI (1.08, 4.48), p = 0.029) as independent risk factors for VAP.Conclusion: Hyperoxemia is independently associated with VAP. Further studies are required to confirm our results. [ABSTRACT FROM AUTHOR]
Copyright of Critical Care is the property of BioMed Central and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:13648535
DOI:10.1186/s13054-016-1368-4