Fabrication and performance of a μRWELL detector with Diamond-Like Carbon resistive electrode and two-dimensional readout

التفاصيل البيبلوغرافية
العنوان: Fabrication and performance of a μRWELL detector with Diamond-Like Carbon resistive electrode and two-dimensional readout
المؤلفون: Ming Shao, Zhiyong Zhang, Daojin Hong, Jianxin Feng, You Lv, Jianbei Liu, Song Guofeng, Yi Zhou, Wang Xu, Shang Lunlin
المصدر: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 927:31-36
بيانات النشر: Elsevier BV, 2019.
سنة النشر: 2019
مصطلحات موضوعية: Physics, Nuclear and High Energy Physics, Resistive touchscreen, Fabrication, Diamond-like carbon, 010308 nuclear & particles physics, business.industry, Detector, STRIPS, Sputter deposition, 01 natural sciences, Cathode, 030218 nuclear medicine & medical imaging, law.invention, 03 medical and health sciences, 0302 clinical medicine, law, 0103 physical sciences, Electrode, Optoelectronics, business, Instrumentation
الوصف: The Micro-Resistive WELL ( μ RWELL) detector is a novel spark-protected Micro-Pattern Gaseous Detector (MPGD) with a single well-type amplification stage. By integrating a well-type amplification structure with a resistive electrode on a readout board ( μ RWELL PCB), the μ RWELL detector is only composed of a cathode PCB and a μ RWELL PCB, resulting in a very simple assembling process without any gluing, stretching, tensioning or other complicated operation commonly practiced in assemblies of other MPGDs. A critical component of the μ RWELL detector is the resistive electrode that is responsible for spark suppression, and hence maintains stable operation of the detector. In this paper, we present a 10 cm × 10 cm μ RWELL detector with two layers readout strips perpendicular to each other. Its resistive electrode is made of a thin coating of Diamond-Like Carbon by magnetron sputtering technique. The gain performance and rate capability of this μ RWELL detector were systematically studied with X-rays, and its detection efficiency and spatial resolution were measured with a test beam. The detector can achieve a spatial resolution better than 70 μ m in both dimensions while the detection efficiency is higher than 90%.
تدمد: 0168-9002
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_________::f621d2dc1409c47d6b3338bc79a60e76Test
https://doi.org/10.1016/j.nima.2019.01.036Test
حقوق: CLOSED
رقم الانضمام: edsair.doi...........f621d2dc1409c47d6b3338bc79a60e76
قاعدة البيانات: OpenAIRE