دورية أكاديمية

Automation of intracoronary continuous thermodilution for absolute coronary flow and microvascular resistance measurements.

التفاصيل البيبلوغرافية
العنوان: Automation of intracoronary continuous thermodilution for absolute coronary flow and microvascular resistance measurements.
المؤلفون: Candreva, A., Gallinoro, E., Fernandez Peregrina, E., Sonck, J., Keulards, DCJ, Van't Veer, M., Mizukami, T., Pijls, NHJ, Collet, C., De Bruyne, B.
المصدر: Catheterization and cardiovascular interventions, vol. 100, no. 2, pp. 199-206
سنة النشر: 2022
المجموعة: Université de Lausanne (UNIL): Serval - Serveur académique lausannois
مصطلحات موضوعية: Automation, Coronary Circulation, Coronary Vessels, Humans, Hyperemia, Microcirculation, Thermodilution/methods, Treatment Outcome, Vascular Resistance, continuous intracoronary thermodilution, coronary flow reserve, coronary physiology, microvascular function, microvascular resistance reserve
الوصف: Microvascular resistance reserve (MRR) as derived from continuous intracoronary thermodilution specifically quantifies microvasculature function. As originally described, the technique necessitates reinstrumentation of the artery and manual reprogramming of the infusion pump when performing resting and hyperemic measurements. To simplify and to render this procedure operator-independent, we developed a fully automated method. The aim of the present study is to validate the automated procedure against the originally described one. For the automated procedure, an infusion pump was preprogrammed to allow paired resting-hyperemic thermodilution assessment without interruption. To validate the accuracy of this new approach, 20 automated measurements were compared to those obtained in the same vessels with conventional paired resting-hyperemic thermodilution measurements (i.e., with a sensor pullback at each infusion rate and manual reprogramming of the infusion pump). A close correlation between the conventional and the automated measuring technique was found for resting flow (Q rest : r = 0.89, mean bias = 2.52; SD = 15.47), hyperemic flow (Q hyper : r = 0.88, mean bias = -2.65; SD = 27.96), resting microvascular resistance (R μ-rest : r = 0.90, mean bias = 52.14; SD = 228.29), hyperemic microvascular resistance R μ-hyper : r = 0.92, mean bias = 12.95; SD = 57.80), and MRR (MRR: r = 0.89, mean bias = 0.04, SD = 0.59). Procedural time was significantly shorter with the automated method (5'25″ ± 1'23″ vs. 4'36″ ± 0'33″, p = 0.013). Continuous intracoronary thermodilution-derived measurements of absolute flow, absolute resistance, and MRR can be fully automated. This further shortens and simplifies the procedure when performing paired resting-hyperemic measurements.
نوع الوثيقة: article in journal/newspaper
اللغة: English
تدمد: 1522-1946
العلاقة: info:eu-repo/semantics/altIdentifier/pmid/35723684; info:eu-repo/semantics/altIdentifier/eissn/1522-726X; https://serval.unil.ch/notice/serval:BIB_71C8B96660D6Test; urn:issn:1522-1946
DOI: 10.1002/ccd.30244
الإتاحة: https://doi.org/10.1002/ccd.30244Test
https://serval.unil.ch/notice/serval:BIB_71C8B96660D6Test
رقم الانضمام: edsbas.E83594FE
قاعدة البيانات: BASE
الوصف
تدمد:15221946
DOI:10.1002/ccd.30244