Closed-Loop Control Without Meal Announcement in Type 1 Diabetes

التفاصيل البيبلوغرافية
العنوان: Closed-Loop Control Without Meal Announcement in Type 1 Diabetes
المؤلفون: Camilla Levister, Bruce A. Buckingham, David W. Lam, Daniel P. Howsmon, Gregory P. Forlenza, Faye Cameron, Yan Yan Xie, Laurel H. Messer, B. Wayne Bequette, Carol J. Levy, Emily Westfall, Trang T. Ly, Paula Clinton, David M. Maahs, Stephen D. Patek, Nihat Baysal
المصدر: Diabetes Technology & Therapeutics. 19:527-532
بيانات النشر: Mary Ann Liebert Inc, 2017.
سنة النشر: 2017
مصطلحات موضوعية: Adult, Blood Glucose, Male, Pancreas, Artificial, Risk, Insulin pump, Research design, medicine.medical_specialty, Endocrinology, Diabetes and Metabolism, 030209 endocrinology & metabolism, Artificial pancreas, Young Adult, 03 medical and health sciences, 0302 clinical medicine, Endocrinology, Control theory, Diabetes mellitus, Accelerometry, Activities of Daily Living, Materials Testing, medicine, Humans, 030212 general & internal medicine, Exercise, Meals, Simulation, Meal, Type 1 diabetes, business.industry, Original Articles, medicine.disease, Hypoglycemia, United States, Hospitalization, Medical Laboratory Technology, Diabetes Mellitus, Type 1, Basal (medicine), Hyperglycemia, Physical therapy, Feasibility Studies, Female, Snacks, business, Algorithms, Follow-Up Studies
الوصف: A fully closed-loop insulin-only system was developed to provide glucose control in patients with type 1 diabetes without requiring announcement of meals or activity. Our goal was to assess initial safety and efficacy of this system.The multiple model probabilistic controller (MMPPC) anticipates meals when the patient is awake. The controller used the subject's basal rates and total daily insulin dose for initialization. The system was tested at two sites on 10 patients in a 30-h inpatient study, followed by 15 subjects at three sites in a 54-h supervised hotel study, where the controller was challenged by exercise and unannounced meals. The system was implemented on the UVA DiAs system using a Roche Spirit Combo Insulin Pump and a Dexcom G4 Continuous Glucose Monitor.The mean overall (24-h basis) and nighttime (11 PM-7 AM) continuous glucose monitoring (CGM) values were 142 and 125 mg/dL during the inpatient study. The hotel study used a different daytime tuning and manual announcement, instead of automatic detection, of sleep and wake periods. This resulted in mean overall (24-h basis) and nighttime CGM values of 152 and 139 mg/dL for the hotel study and there was also a reduction in hypoglycemia events from 1.6 to 0.91 events/patient/day.The MMPPC system achieved a mean glucose that would be particularly helpful for people with an elevated A1c as a result of frequent missed meal boluses. Current full closed loop has a higher risk for hypoglycemia when compared with algorithms using meal announcement.
تدمد: 1557-8593
1520-9156
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::f8ae6432ae56c0e7d69511892be53307Test
https://doi.org/10.1089/dia.2017.0078Test
حقوق: OPEN
رقم الانضمام: edsair.doi.dedup.....f8ae6432ae56c0e7d69511892be53307
قاعدة البيانات: OpenAIRE