دورية أكاديمية

Experimental validation and clinical feasibility of 3D reconstruction of coronary artery bifurcation stents using intravascular ultrasound.

التفاصيل البيبلوغرافية
العنوان: Experimental validation and clinical feasibility of 3D reconstruction of coronary artery bifurcation stents using intravascular ultrasound.
المؤلفون: Wu, Wei, Banga, Akshat, Oguz, Usama M., Zhao, Shijia, Thota, Anjani Kumar, Gadamidi, Vinay Kumar, Dasari, Vineeth S., Samant, Saurabhi, Watanabe, Yusuke, Murasato, Yoshinobu, Chatzizisis, Yiannis S.
المصدر: PLoS ONE; 4/16/2024, Vol. 19 Issue 4, p1-21, 21p
مصطلحات موضوعية: INTRAVASCULAR ultrasonography, CORONARY arteries, COMPUTATIONAL fluid dynamics, SURGICAL stents
مستخلص: The structural morphology of coronary stents and the local hemodynamic environment following stent deployment in coronary arteries are crucial determinants of procedural success and subsequent clinical outcomes. High-resolution intracoronary imaging has the potential to facilitate geometrically accurate three-dimensional (3D) reconstruction of coronary stents. This work presents an innovative algorithm for the 3D reconstruction of coronary artery stents, leveraging intravascular ultrasound (IVUS) and angiography. The accuracy and reproducibility of our method were tested in stented patient-specific silicone models, with micro-computed tomography serving as a reference standard. We also evaluated the clinical feasibility and ability to perform computational fluid dynamics (CFD) studies in a clinically stented coronary bifurcation. Our experimental and clinical studies demonstrated that our proposed algorithm could reproduce the complex 3D stent configuration with a high degree of precision and reproducibility. Moreover, the algorithm was proved clinically feasible in cases with stents deployed in a diseased coronary artery bifurcation, enabling CFD studies to assess the hemodynamic environment. In combination with patient-specific CFD studies, our method can be applied to stenting optimization, training in stenting techniques, and advancements in stent research and development. [ABSTRACT FROM AUTHOR]
Copyright of PLoS ONE is the property of Public Library of Science and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:19326203
DOI:10.1371/journal.pone.0300098