A 'signal-on’’ aptasensor for simultaneous detection of chloramphenicol and polychlorinated biphenyls using multi-metal ions encoded nanospherical brushes as tracers

التفاصيل البيبلوغرافية
العنوان: A 'signal-on’’ aptasensor for simultaneous detection of chloramphenicol and polychlorinated biphenyls using multi-metal ions encoded nanospherical brushes as tracers
المؤلفون: Yuting Cao, Yinji Chen, Zhongdan Yan, De Wang, Ning Gan, Tianhua Li, Meng Chen
المصدر: Biosensors and Bioelectronics. 74:718-724
بيانات النشر: Elsevier BV, 2015.
سنة النشر: 2015
مصطلحات موضوعية: Analyte, Conductometry, Aptamer, Metal ions in aqueous solution, Inorganic chemistry, Biomedical Engineering, Biophysics, Magnetic separation, Metal Nanoparticles, Biosensing Techniques, Complex Mixtures, Electrochemistry, Animals, Multiplex, Magnetite Nanoparticles, Chromatography, Chemistry, Fishes, Equipment Design, General Medicine, Aptamers, Nucleotide, Polychlorinated Biphenyls, Equipment Failure Analysis, Chloramphenicol, Colloidal gold, Environmental Pollutants, Gold, Selectivity, Biosensor, Environmental Monitoring, Biotechnology
الوصف: A “signal-on’’ aptasensor was developed for simultaneous detection of chloramphenicols (CAP) and polychlorinated biphenyl-72 (PCB72) with a novel multi-metal ions encoded nanospherical brushes as nanotracers. To construct the assay, the respective aptamer of CAP and PCB72 labeled magnetic gold nanoparticles as capture probes (aptamer-MGPs), and their complementary single strand DNA (s-DNA) encoded metal ions (Cd 2+ and Pb 2+ ) on nanospherical branched polyethylene imine brushes as tracers (s-DNA-MSPEIs), were simultaneously synthesized. After that, the capture probe and tracers were connected through a hybridization reaction between s-DNA and aptamers. In the presence of CAP and PCB72, the analytes could react with the aptamers on capture probes and release the tracers into supernatant after magnetic separation. The released tracers with metal ions (Cd 2+ and Pb 2+ ) could be simultaneously detected through the square wave voltammetry (SWV) without acid dissolution, which can switch the signals of the biosensor to “on’’ state. Under optimal conditions, the assay could detect CAP and PCB72 as low as 0.3 pg mL −1 with the dynamitic range from 0.001 to 100 ng mL −1 and exhibited excellent selectivity. More importantly, the strategy can be extended easily to other targets after changing the corresponding aptamers and other metal ions tracers, which provides a promising and facile approach in multiplex detection of ultra-trace level of pollutants in food safety without more complex separation and washing steps.
تدمد: 0956-5663
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::73378ebe56c20a84fc901516dfdee766Test
https://doi.org/10.1016/j.bios.2015.07.024Test
حقوق: CLOSED
رقم الانضمام: edsair.doi.dedup.....73378ebe56c20a84fc901516dfdee766
قاعدة البيانات: OpenAIRE