دورية أكاديمية

Quantitative measurement of normal and hydrocephalic cerebrospinal fluid flow using phase contrast cine MR imaging.

التفاصيل البيبلوغرافية
العنوان: Quantitative measurement of normal and hydrocephalic cerebrospinal fluid flow using phase contrast cine MR imaging.
المؤلفون: Katayama, Shinji, Asari, Shoji, Ohmoto, Takashi
المصدر: Acta Medica Okayama
بيانات النشر: Okayama University Medical School
سنة النشر: 2016
المجموعة: Okayama University Scientific Achievement Repository / 岡山大学学術成果リポジトリ
مصطلحات موضوعية: cerebrospinal fluid flow, normal pressure hydrocephalus, magnetic resonance imaging, phase contrast
الوصف: Measurements of the cerebrospinal fluid (CSF) flow using phase contrast cine magnetic resonance (MR) imaging were performed on a phantom, 12 normal subjects and 20 patients with normal pressure hydrocephalus (NPH). The phantom study demonstrated the applicability of phase contrast in quantitative measurement of the slow flow. The CSF flows of the normal subjects showed a consistent pattern with a to-and-fro movement of the flow in the anterior subarachnoid space at the C2/3 level, and they were dependent on the cardiac cycle in all subjects. However, the patients with NPH showed variable patterns of the CSF pulsatile flow and these patterns could be divided into four types according to velocity and amplitude. The amplitudes of each type were as follows: type 0 (n = 1), 87.6mm; type I (n = 2), 58.2mm (mean); type II (n = 6), 48.0 +/- 5.0mm (mean +/- SEM); and type III (n = 11), 19.9 +/- 1.8mm (mean +/- SEM). The decrease of the amplitudes correlated to a worsening of the clinical symptoms. After the shunting operation, the amplitude of to-and-fro movement of the CSF increased again in the patients with NPH who improved clinically. Some of the type III cases were reclassified type II, I and 0 and also one of the type II cases changed type I after the shunting operation. We conclude that the phase contrast cine MR imaging is a practically and clinically applicable technique for the quantitative measurement of the CSF flow.
نوع الوثيقة: article in journal/newspaper
اللغة: English
تدمد: 0386-300X
العلاقة: info:pmid/8379344; https://ousar.lib.okayama-u.ac.jp/files/public/3/31595/20160528023050488633/fulltext.pdfTest; AA00508441; https://ousar.lib.okayama-u.ac.jp/31595Test
DOI: 10.18926/AMO/31595
الإتاحة: https://doi.org/10.18926/AMO/31595Test
https://ousar.lib.okayama-u.ac.jp/files/public/3/31595/20160528023050488633/fulltext.pdfTest
https://ousar.lib.okayama-u.ac.jp/31595Test
رقم الانضمام: edsbas.41C39E62
قاعدة البيانات: BASE
الوصف
تدمد:0386300X
DOI:10.18926/AMO/31595