دورية أكاديمية

Safety and efficacy of high-rate cutoff and long detection interval ICD programming in secondary prevention patients.

التفاصيل البيبلوغرافية
العنوان: Safety and efficacy of high-rate cutoff and long detection interval ICD programming in secondary prevention patients.
المؤلفون: Hayashi, Yusuke, Takagi, Masahiko, Kakihara, Jun, Sakamoto, Shogo, Doi, Atsushi, Sugioka, Kenichi, Hanatani, Akihisa, Yoshiyama, Minoru
المصدر: Heart & Vessels; Feb2017, Vol. 32 Issue 2, p175-185, 11p
مصطلحات موضوعية: IMPLANTABLE cardioverter-defibrillators, SYNCOPE, CARDIAC pacing, FOLLOW-up studies (Medicine), HOSPITAL care, PREVENTION, SAFETY
مستخلص: Several trials demonstrated that a long detection interval and a high-rate cutoff reduced implantable cardioverter-defibrillator (ICD) therapy in primary prevention patients. However, only a few data are available for secondary prevention (SP) patients. The aim of this study was to evaluate whether these ICD programming would be effective in reducing ICD therapies in SP patients. We enrolled 65 SP patients under ICD or cardiac resynchronization therapy with the defibrillator programmed with the same setting (conventional setting). During follow-up, we changed detection rates in each zone; cycle length (CL) ≤400 to ≤370 ms for ventricular tachycardia (VT) zone, CL ≤350 to ≤320 ms for fast VT zone, CL ≤300 to ≤270 ms for ventricular fibrillation (VF) zone, and number of intervals to detect ventricular tachyarrhythmia in VF zone: 12-24. We retrospectively compared the incidences of ICD therapies, syncope, and hospitalization due to slow VT under the detection rate between both settings. Median follow-up periods were 5.0 (interquartile range 2.5-7.8) and 2.5 years (interquartile range 2.3-2.7) in conventional and strategic settings, respectively. The incidence of appropriate ATP and shock significantly decreased in strategic setting (conventional and strategic settings: 21.2 and 4.8 ATPs per year, respectively, OR 0.18, 95 % CI 0.06-0.54, p = 0.002, 26.1 and 7.8 shocks per year, respectively, OR 0.29, 95 % CI 0.09-0.88, p = 0.03). The incidence of overall inappropriate therapy significantly decreased (conventional and strategic settings: 17.6 and 2.8 therapies per year, respectively, OR 0.14, 95 % CI 0.05-0.44, p = 0.01). The incidence of syncope and slow VT was not significantly different between both settings. In conclusion, ICD programming-combined long detection interval with high-rate cutoff was effective in reducing appropriate shock and inappropriate therapy without increasing the incidence of syncope and slow VT in SP patients. [ABSTRACT FROM AUTHOR]
Copyright of Heart & Vessels is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:09108327
DOI:10.1007/s00380-016-0850-x