دورية أكاديمية

Detection of artificial pulmonary lung nodules in ultralow-dose CT using an ex vivo lung phantom.

التفاصيل البيبلوغرافية
العنوان: Detection of artificial pulmonary lung nodules in ultralow-dose CT using an ex vivo lung phantom.
المؤلفون: Burgard, Caroline Alexandra, Gaass, Thomas, Bonert, Madeleine, Bondesson, David, Thaens, Natalie, Reiser, Maximilian Ferdinand, Dinkel, Julien
المصدر: PLoS ONE; 1/3/2018, Vol. 13 Issue 1, p1-11, 11p
مصطلحات موضوعية: CHEST examination, IMAGE quality analysis, COMPUTED tomography, RADIATION doses, MECHANICAL ventilators
مستخلص: Objectives: To assess the image quality of 3 different ultralow-dose CT protocols on pulmonary nodule depiction in a ventilated ex vivo-system. Materials and methods: Four porcine lungs were inflated inside a dedicated chest phantom and prepared with n = 195 artificial nodules (0.5–1 mL). The artificial chest wall was filled with water to simulate the absorption of a human chest. Images were acquired with a 2x192-row detector CT using low-dose (reference protocol with a tube voltage of 120 kV) and 3 different ULD protocols (respective effective doses: 1mSv and 0.1mSv). A different tube voltage was used for each ULD protocol: 70kV, 100kV with tin filter (100kV_Sn) and 150kV with tin filter (150kV_Sn). Nodule delineation was assessed by two observers (scores 1–5, 1 = unsure, 5 = high confidence). Results: The diameter of the 195 detected artificial nodules ranged from 0.9–21.5 mm (mean 7.84 mm ± 5.31). The best ULD scores were achieved using 100kV_Sn and 70 kV ULD protocols (4.14 and 4.06 respectively). Both protocols were not significantly different (p = 0.244). The mean score of 3.78 in ULD 150kV_Sn was significantly lower compared to the 100kV_Sn ULD protocol (p = 0.008). Conclusion: The results of this experiment, conducted in a realistic setting show the feasibility of ultralow-dose CT for the detection of pulmonary nodules. [ABSTRACT FROM AUTHOR]
Copyright of PLoS ONE is the property of Public Library of Science and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:19326203
DOI:10.1371/journal.pone.0190501