دورية أكاديمية

Establishing the European diagnostic reference levels for interventional cardiology

التفاصيل البيبلوغرافية
العنوان: Establishing the European diagnostic reference levels for interventional cardiology
المؤلفون: Siiskonen, T., Ciraj-Bjelac, O., Dabin, J., Diklic, A., Domienik-Andrzejewska, J., Farah, J., Fernandez, J.M., Gallagher, A., Hourdakis, C.J., Jurković, Slaven, Järvinen, H., Järvinen, J., Knežević, Ž., Koukorava, C., Maccia, C., Majer, M., Malchair, F., Riccardi, L., Rizk, C., Sanchez, R., Sandborg, M., Merce, M. Sans, Šegota, D., Sierpowska, J., Simantirakis, G., Sukupova, L., Thrapsanioti, Z., Vano, E.
المصدر: https://linkinghub.elsevier.com/retrieve/pii/S1120179718311748Test ; Physica Medica ; Volume 54 ; ISSN 1120-1797 (Print.
سنة النشر: 2018
المجموعة: Repository of the University of Rijeka
مصطلحات موضوعية: European diagnostic reference levels, intervenional cardiology, CA, PCI, TAVI, electrophysiological procedures and pacemaker implantations, PRIRODNE ZNANOSTI. Fizika, NATURAL SCIENCES. Physics, BIOMEDICINA I ZDRAVSTVO. Kliničke medicinske znanosti. Radiologija, BIOMEDICINE AND HEALTHCARE. Clinical Medical Sciences. Radiology
الوصف: Interventional cardiac procedures may be associated with high patient doses and therefore require special attention to protect the patients from radiation injuries such as skin erythema, cardiovascular tissue reactions or radiation-induced cancer. In this study, patient exposure data is collected from 13 countries (37 clinics and nearly 50 interventional rooms) and for 10 different procedures. Dose data was collected from a total of 14, 922 interventional cardiology procedures. Based on these data European diagnostic reference levels (DRL) for air kerma-area product are suggested for coronary angiography (CA, DRL = 35 Gy cm2), percutaneous coronary intervention (PCI, 85 Gy cm2), transcatheter aortic valve implantation (TAVI, 130 Gy cm2), electrophysiological procedures (12 Gy cm2) and pacemaker implantations. Pacemaker implantations were further divided into single-chamber (2.5 Gy cm2) and dual chamber (3.5 Gy cm2) procedures and implantations of cardiac resynchronization therapy pacemaker (18 Gy cm2). Results show that relatively new techniques such as TAVI and treatment of chronic total occlusion (CTO) often produce relatively high doses, and thus emphasises the need for use of an optimization tool such as DRL to assist in reducing patient exposure. The generic DRL presented here facilitate comparison of patient exposure in interventional cardiology.
نوع الوثيقة: article in journal/newspaper
وصف الملف: application/pdf
اللغة: English
ردمك: 978-1-120-17971-5
1-120-17971-8
العلاقة: Sveučilište u Rijeci. Medicinski fakultet. Katedra za medicinsku fiziku i biofiziku.; University of Rijeka. Faculty of Medicine. Department of Medical Physics and Biophysics.; https://www.unirepository.svkri.uniri.hr/islandora/object/medri:5213Test; https://urn.nsk.hr/urn:nbn:hr:184:065588Test; https://www.unirepository.svkri.uniri.hr/islandora/object/medri:5213/datastream/FILE0Test
الإتاحة: https://doi.org/10.1016/j.ejmp.2018.09.012Test
https://www.unirepository.svkri.uniri.hr/islandora/object/medri:5213Test
https://urn.nsk.hr/urn:nbn:hr:184:065588Test
https://www.unirepository.svkri.uniri.hr/islandora/object/medri:5213/datastream/FILE0Test
حقوق: info:eu-repo/semantics/restrictedAccess ; http://rightsstatements.org/vocab/InC/1.0Test/
رقم الانضمام: edsbas.61AB9E02
قاعدة البيانات: BASE