دورية أكاديمية
Establishing the European diagnostic reference levels for interventional cardiology
العنوان: | Establishing the European diagnostic reference levels for interventional cardiology |
---|---|
المؤلفون: | Siiskonen, T., Ciraj-Bjelac, O., Dabin, J., Diklic, A., Domienik-Andrzejewska, J., Farah, J., Fernandez, J.M., Gallagher, A., Hourdakis, C.J., Jurković, Slaven, Järvinen, H., Järvinen, J., Knežević, Ž., Koukorava, C., Maccia, C., Majer, M., Malchair, F., Riccardi, L., Rizk, C., Sanchez, R., Sandborg, M., Merce, M. Sans, Šegota, D., Sierpowska, J., Simantirakis, G., Sukupova, L., Thrapsanioti, Z., Vano, E. |
المصدر: | https://linkinghub.elsevier.com/retrieve/pii/S1120179718311748Test ; Physica Medica ; Volume 54 ; ISSN 1120-1797 (Print. |
سنة النشر: | 2018 |
المجموعة: | Repository of the University of Rijeka |
مصطلحات موضوعية: | European diagnostic reference levels, intervenional cardiology, CA, PCI, TAVI, electrophysiological procedures and pacemaker implantations, PRIRODNE ZNANOSTI. Fizika, NATURAL SCIENCES. Physics, BIOMEDICINA I ZDRAVSTVO. Kliničke medicinske znanosti. Radiologija, BIOMEDICINE AND HEALTHCARE. Clinical Medical Sciences. Radiology |
الوصف: | Interventional cardiac procedures may be associated with high patient doses and therefore require special attention to protect the patients from radiation injuries such as skin erythema, cardiovascular tissue reactions or radiation-induced cancer. In this study, patient exposure data is collected from 13 countries (37 clinics and nearly 50 interventional rooms) and for 10 different procedures. Dose data was collected from a total of 14, 922 interventional cardiology procedures. Based on these data European diagnostic reference levels (DRL) for air kerma-area product are suggested for coronary angiography (CA, DRL = 35 Gy cm2), percutaneous coronary intervention (PCI, 85 Gy cm2), transcatheter aortic valve implantation (TAVI, 130 Gy cm2), electrophysiological procedures (12 Gy cm2) and pacemaker implantations. Pacemaker implantations were further divided into single-chamber (2.5 Gy cm2) and dual chamber (3.5 Gy cm2) procedures and implantations of cardiac resynchronization therapy pacemaker (18 Gy cm2). Results show that relatively new techniques such as TAVI and treatment of chronic total occlusion (CTO) often produce relatively high doses, and thus emphasises the need for use of an optimization tool such as DRL to assist in reducing patient exposure. The generic DRL presented here facilitate comparison of patient exposure in interventional cardiology. |
نوع الوثيقة: | article in journal/newspaper |
وصف الملف: | application/pdf |
اللغة: | English |
ردمك: | 978-1-120-17971-5 1-120-17971-8 |
العلاقة: | Sveučilište u Rijeci. Medicinski fakultet. Katedra za medicinsku fiziku i biofiziku.; University of Rijeka. Faculty of Medicine. Department of Medical Physics and Biophysics.; https://www.unirepository.svkri.uniri.hr/islandora/object/medri:5213Test; https://urn.nsk.hr/urn:nbn:hr:184:065588Test; https://www.unirepository.svkri.uniri.hr/islandora/object/medri:5213/datastream/FILE0Test |
الإتاحة: | https://doi.org/10.1016/j.ejmp.2018.09.012Test https://www.unirepository.svkri.uniri.hr/islandora/object/medri:5213Test https://urn.nsk.hr/urn:nbn:hr:184:065588Test https://www.unirepository.svkri.uniri.hr/islandora/object/medri:5213/datastream/FILE0Test |
حقوق: | info:eu-repo/semantics/restrictedAccess ; http://rightsstatements.org/vocab/InC/1.0Test/ |
رقم الانضمام: | edsbas.61AB9E02 |
قاعدة البيانات: | BASE |
ردمك: | 9781120179715 1120179718 |
---|