دورية أكاديمية

The effect of time-of-day and chest physiotherapy on multiple breath washout measures in children with clinically stable cystic fibrosis.

التفاصيل البيبلوغرافية
العنوان: The effect of time-of-day and chest physiotherapy on multiple breath washout measures in children with clinically stable cystic fibrosis.
المؤلفون: Voldby, Christian, Green, Kent, Rosthøj, Susanne, Kongstad, Thomas, Philipsen, Lue, Buchvald, Frederik, Skov, Marianne, Pressler, Tania, Gustafsson, Per, Nielsen, Kim G.
المصدر: PLoS ONE; 1/10/2018, Vol. 13 Issue 1, p1-15, 15p
مصطلحات موضوعية: PULMONARY function tests, CYSTIC fibrosis in children, PLETHYSMOGRAPHY, SPIROMETRY, CHEST physiology, THERAPEUTICS
مستخلص: Background: In this pilot study we investigated daytime variation of multiple breath nitrogen washout (N2MBW) measures in children with clinically stable cystic fibrosis. To our knowledge the effect of time-of-day on multiple breath washout measures in patients with cystic fibrosis has not previously been reported. Furthermore, we assessed the influence of chest physiotherapy on N2MBW measures. Methods: Ten school children with cystic fibrosis performed N2MBW followed by spirometry and plethysmography in the morning and afternoon at three visits that were one month apart. Chest physiotherapy was performed immediately before the afternoon measurements at visit 2 and immediately before morning and afternoon measurements at visit 3. The influence of time-of-day and chest physiotherapy on the measures was evaluated using linear mixed models. Results: There were adequate quality data from 8 children with median age (range) 9.6 (6.0; 15.1) years. Baseline lung clearance index (LCI) (range) was 9.0 (7.1; 13.0) and baseline FEV1% predicted was 97.5 (78.5; 117.9). No N2MBW measures were significantly influenced by time-of-day or chest physiotherapy. LCI (95% confidence interval) decreased non-significantly 0.05 (-0.32; 0.22) during the day and increased non-significantly 0.08 (-0.26; 0.42) after chest physiotherapy. All spirometric measures were unaffected by time-of-day and chest physiotherapy. For plethysmographic measures FRCpleth decreased significantly (p<0.01) 110 mL during the day, whereas a borderline significant (p = 0.046) decrease in ΔFRCpleth-MBW during the day and a borderline significant (p = 0.03) increase in TLC after CPT were observed. Conclusion: This study demonstrated that the time-of-day as well as chest physiotherapy performed immediately prior to N2MBW had no consistent or significant influence on N2MBW measures. However, we emphasize that further studies of the effect of both daytime variation and the effect of chest physiotherapy on multiple breath washout measures are warranted. [ABSTRACT FROM AUTHOR]
Copyright of PLoS ONE is the property of Public Library of Science and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:19326203
DOI:10.1371/journal.pone.0190894