Evaluation of a novel patient-specific quality assurance phantom for robotic single-isocentre, multiple-target stereotactic radiosurgery, and stereotactic radiotherapy.

التفاصيل البيبلوغرافية
العنوان: Evaluation of a novel patient-specific quality assurance phantom for robotic single-isocentre, multiple-target stereotactic radiosurgery, and stereotactic radiotherapy.
المؤلفون: Xu, Qianyi, Vinogradskiy, Yevgeniy, Grimm, Jimm, Nie, Wei, Dupre, Pamela, Chawla, Ashish K, Bajaj, Gopal, Yang, Haihua, LaCouture, Tamara, Fan, Jiajin
المصدر: British Journal of Radiology; Mar2024, Vol. 97 Issue 1155, p660-667, 8p
مصطلحات موضوعية: STEREOTACTIC radiotherapy, STEREOTACTIC radiosurgery, QUALITY assurance, SURGICAL robots, ROBOTICS, TRACKING radar
مستخلص: Objectives To evaluate patient-specific quality assurance (PSQA) of 3 targets in a single delivery using a novel film-based phantom. Methods The phantom was designed to rotate freely as a sphere and could measure 3 targets with film in a single delivery. After identifying the coordinates of 3 targets in the skull, the rotation angles about the equator and meridian were computed for optimal phantom setup, ensuring the film plane intersected the 3 targets. The plans were delivered on the CyberKnife system using fiducial tracking. The irradiated films were scanned and processed. All films were analysed using 3 gamma criteria. Results Fifteen CyberKnife test plans with 3 different modalities were delivered on the phantom. Both automatic and marker-based registration methods were applied when registering the irradiated film and dose plane. Gamma analysis was performed using a 3%/1 mm, 2%/1 mm, and 1%/1 mm criteria with a 10% threshold. For the automatic registration method, the passing rates were 98.2% ± 1.9%, 94.2% ± 3.7%, and 80.9% ± 6.3%, respectively. For the marker-based registration approach, the passing rates were 96.4% ± 2.7%, 91.7% ± 4.3%, and 78.4% ± 6.2%, respectively. Conclusions A novel spherical phantom was evaluated for the CyberKnife system and achieved acceptable PSQA passing rates using TG218 recommendations. The phantom can measure true-composite dose and offers high-resolution results for PSQA, making it a valuable device for robotic radiosurgery. Advances in knowledge This is the first study on PSQA of 3 targets concurrently on the CyberKnife system. [ABSTRACT FROM AUTHOR]
Copyright of British Journal of Radiology is the property of Oxford University Press / USA and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:00071285
DOI:10.1093/bjr/tqae011