دورية أكاديمية

Current worldwide nuclear cardiology practices and radiation exposure : results from the 65 country IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS)

التفاصيل البيبلوغرافية
العنوان: Current worldwide nuclear cardiology practices and radiation exposure : results from the 65 country IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS)
المؤلفون: Einstein, Andrew J., Pascual, Thomas N. B., Mercuri, Mathew, Karthikeyan, Ganesan, Vitola, João V., Mahmarian, John J., Better, Nathan, Bouyoucef, Salah E., Hee-Seung Bom, Henry, Lele, Vikram, Magboo, V. Peter C., Alexánderson, Erick, Allam, Adel H., Al-Mallah, Mouaz H., Flotats, Albert, Jerome, Scott, Kaufmann, Philipp A., Luxenburg, Osnat, Shaw, Leslee J., Underwood, S. Richard, Rehani, Madan M., Kashyap, Ravi, Paez, Diana, Dondi, Maurizio, Universitat Autònoma de Barcelona
سنة النشر: 2015
المجموعة: Universitat Autònoma de Barcelona: Dipòsit Digital de Documents de la UAB
مصطلحات موضوعية: Nuclear cardiology, SPECT, PET, Radiation dose, Best practices, Quality of care
الوصف: To characterize patient radiation doses from nuclear myocardial perfusion imaging (MPI) and the use of radiation-optimizing 'best practices' worldwide, and to evaluate the relationship between laboratory use of best practices and patient radiation dose. We conducted an observational cross-sectional study of protocols used for all 7911 MPI studies performed in 308 nuclear cardiology laboratories in 65 countries for a single week in March-April 2013. Eight 'best practices' relating to radiation exposure were identified a priori by an expert committee, and a radiation-related quality index (QI) devised indicating the number of best practices used by a laboratory. Patient radiation effective dose (ED) ranged between 0.8 and 35.6 mSv (median 10.0 mSv). Average laboratory ED ranged from 2.2 to 24.4 mSv (median 10.4 mSv); only 91 (30%) laboratories achieved the median ED ≤ 9 mSv recommended by guidelines. Laboratory QIs ranged from 2 to 8 (median 5). Both ED and QI differed significantly between laboratories, countries, and world regions. The lowest median ED (8.0 mSv), in Europe, coincided with high best-practice adherence (mean laboratory QI 6.2). The highest doses (median 12.1 mSv) and low QI (4.9) occurred in Latin America. In hierarchical regression modelling, patients undergoing MPI at laboratories following more 'best practices' had lower EDs. Marked worldwide variation exists in radiation safety practices pertaining to MPI, with targeted EDs currently achieved in a minority of laboratories. The significant relationship between best-practice implementation and lower doses indicates numerous opportunities to reduce radiation exposure from MPI globally.
نوع الوثيقة: article in journal/newspaper
وصف الملف: application/pdf
اللغة: English
تدمد: 15229645
العلاقة: European heart journal; Vol. 36 (april 2015), p. 1689-1696; https://ddd.uab.cat/record/185312Test; urn:10.1093/eurheartj/ehv117; urn:oai:ddd.uab.cat:185312; urn:pmid:25898845; urn:pmcid:PMC4493324; urn:pmc-uid:4493324; urn:articleid:15229645v36p1689; urn:scopus_id:84942297849; urn:wos_id:000358178100014; urn:altmetric_id:3926759; urn:recercauab:ARE-89928; urn:oai:egreta.uab.cat:publications/9e28b59a-058d-44ab-b63e-41cc47f4983a; urn:oai:egreta.uab.cat:publications/4fee43c4-a614-46cf-8844-951166c5a6b7; urn:oai:pubmedcentral.nih.gov:4493324
الإتاحة: https://ddd.uab.cat/record/185312Test
حقوق: open access ; Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, la comunicació pública de l'obra i la creació d'obres derivades, sempre que no sigui amb finalitats comercials, i sempre que es reconegui l'autoria de l'obra original. ; https://creativecommons.org/licenses/by-nc/4.0Test/
رقم الانضمام: edsbas.B4DDFE90
قاعدة البيانات: BASE