Radiographic Comparison between Cervical Spine Lateral and Whole-Spine Lateral Standing Radiographs

التفاصيل البيبلوغرافية
العنوان: Radiographic Comparison between Cervical Spine Lateral and Whole-Spine Lateral Standing Radiographs
المؤلفون: Jae Keun Oh, Seong Hwan Moon, Tae-Hwan Kim, Hwa Jun Kang, Moon Soo Park, K. Daniel Riew
المصدر: Global Spine Journal
بيانات النشر: Georg Thieme Verlag KG, 2015.
سنة النشر: 2015
مصطلحات موضوعية: Orthodontics, 030222 orthopedics, medicine.medical_specialty, Offset distance, Adult patients, business.industry, cervical spine lateral radiograph, Radiography, whole-spine lateral radiograph, Cervical spine, Article, Surgery, 03 medical and health sciences, 0302 clinical medicine, medicine, Lateral view, Sagittal alignment, Orthopedics and Sports Medicine, Neurology (clinical), business, radiographic comparison, 030217 neurology & neurosurgery
الوصف: Study Design Retrospective radiologic study. Objective The sagittal alignment of the cervical spine can be evaluated using either a lateral cervical radiograph or a whole-spine lateral view on which the cervical spine is included. To our knowledge, however, no report has compared the two. The purpose of this work is to identify the difference in radiographic parameters between the cervical spine lateral view and the whole-spine lateral view. Methods We retrospectively analyzed 59 adult patients suffering from neck pain with cervical spine lateral radiographs and whole-spine lateral radiographs from November 2007 to December 2011. The radiographs were measured using standard techniques to obtain the following parameters from the two different radiographs: occipital–C2 angle, C2–C7 angle, C7–sternal angle, sternal slope, T1 slope, C2 central offset distance, the distance between C2 and C7 plumb lines, C4 anteroposterior (AP) diameter, the ratio of C2 central off distance to C4 AP diameter, the ratio of plumb lines’ distance to C4 AP diameter. Results We found that the occipital–C2 angle, sternal slope, and C4 AP diameter were similar, but the C2–C7 angle, C7–sternal angle, T1 slope, C2 central offset distance, distance between C2 and C7 plumb lines, ratio of C2 central off distance to C4 AP diameter, and ratio of plumb lines’ distance to C4 AP diameter were different. However, the error of measurement was greater than the small angular and linear differences between the two views. Conclusions Most numerical values of the measured radiographic parameters appear to be different between the two views. However, the two views are comparable because the numerical differences were smaller than the errors of measurement.
اللغة: English
تدمد: 2192-5690
2192-5682
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::90e26926f9d35a7bc2dac81fc3166a03Test
http://europepmc.org/articles/PMC4771508Test
حقوق: OPEN
رقم الانضمام: edsair.doi.dedup.....90e26926f9d35a7bc2dac81fc3166a03
قاعدة البيانات: OpenAIRE