العنوان: Fully automated computational measurement of noise in positron emission tomography
المؤلفون: Sartoretti, Thomas, Skawran, Stephan, Gennari, Antonio G., Maurer, Alexander, Euler, André, Treyer, Valerie, Sartoretti, Elisabeth, Waelti, Stephan, Schwyzer, Moritz, von Schulthess, Gustav K., Burger, Irene A., Huellner, Martin W., Messerli, Michael
المصدر: European Radiology, 34 (3)
بيانات النشر: Springer
سنة النشر: 2024
المجموعة: ETH Zürich Research Collection
مصطلحات موضوعية: Positron emission tomography, Noise, Algorithms, Dose reduction, Image enhancement
الوصف: Objectives: To introduce an automated computational algorithm that estimates the global noise level across the whole imaging volume of PET datasets. Methods: [18F]FDG PET images of 38 patients were reconstructed with simulated decreasing acquisition times (15–120 s) resulting in increasing noise levels, and with block sequential regularized expectation maximization with beta values of 450 and 600 (Q.Clear 450 and 600). One reader performed manual volume-of-interest (VOI) based noise measurements in liver and lung parenchyma and two readers graded subjective image quality as sufficient or insufficient. An automated computational noise measurement algorithm was developed and deployed on the whole imaging volume of each reconstruction, delivering a single value representing the global image noise (Global Noise Index, GNI). Manual noise measurement values and subjective image quality gradings were compared with the GNI. Results: Irrespective of the absolute noise values, there was no significant difference between the GNI and manual liver measurements in terms of the distribution of noise values (p = 0.84 for Q.Clear 450, and p = 0.51 for Q.Clear 600). The GNI showed a fair to moderately strong correlation with manual noise measurements in liver parenchyma (r = 0.6 in Q.Clear 450, r = 0.54 in Q.Clear 600, all p < 0.001), and a fair correlation with manual noise measurements in lung parenchyma (r = 0.52 in Q.Clear 450, r = 0.33 in Q.Clear 600, all p < 0.001). Classification performance of the GNI for subjective image quality was AUC 0.898 for Q.Clear 450 and 0.919 for Q.Clear 600. Conclusion: An algorithm provides an accurate and meaningful estimation of the global noise level encountered in clinical PET imaging datasets. Clinical relevance statement: An automated computational approach that measures the global noise level of PET imaging datasets may facilitate quality standardization and benchmarking of clinical PET imaging within and across institutions. Key Points: • Noise is an important quantitative marker ...
نوع الوثيقة: article in journal/newspaper
وصف الملف: application/application/pdf
اللغة: English
العلاقة: http://hdl.handle.net/20.500.11850/661703Test
DOI: 10.3929/ethz-b-000661703
الإتاحة: https://doi.org/20.500.11850/661703Test
https://doi.org/10.3929/ethz-b-000661703Test
https://doi.org/10.1007/s00330-023-10056-wTest
https://hdl.handle.net/20.500.11850/661703Test
حقوق: info:eu-repo/semantics/openAccess ; http://creativecommons.org/licenses/by/4.0Test/ ; Creative Commons Attribution 4.0 International