Aerosol emission from the respiratory tract: an analysis of aerosol generation from oxygen delivery systems.

التفاصيل البيبلوغرافية
العنوان: Aerosol emission from the respiratory tract: an analysis of aerosol generation from oxygen delivery systems.
المؤلفون: Hamilton, Fergus W., Gregson, Florence K. A., Arnold, David T., Sheikh, Sadiyah, Ward, Kirsty, Brown, Jules, Moran, Ed, White, Carrie, Morley, Anna J., Bzdek, Bryan R., Reid, Jonathan P., Maskell, Nicholas A., Dodd, James William, AERATOR Group
المصدر: Thorax; Mar2022, Vol. 77 Issue 3, p276-282, 7p
مصطلحات موضوعية: AEROSOL analysis, COVID-19, AEROSOLS, LAMINAR flow, VOLUNTEER recruitment
مستخلص: Introduction: continuous positive airway pressure (CPAP) and high-flow nasal oxygen (HFNO) provide enhanced oxygen delivery and respiratory support for patients with severe COVID-19. CPAP and HFNO are currently designated as aerosol-generating procedures despite limited high-quality experimental data. We aimed to characterise aerosol emission from HFNO and CPAP and compare with breathing, speaking and coughing.Materials and Methods: Healthy volunteers were recruited to breathe, speak and cough in ultra-clean, laminar flow theatres followed by using CPAP and HFNO. Aerosol emission was measured using two discrete methodologies, simultaneously. Hospitalised patients with COVID-19 had cough recorded using the same methodology on the infectious diseases ward.Results: In healthy volunteers (n=25 subjects; 531 measures), CPAP (with exhalation port filter) produced less aerosol than breathing, speaking and coughing (even with large >50 L/min face mask leaks). Coughing was associated with the highest aerosol emissions of any recorded activity. HFNO was associated with aerosol emission, however, this was from the machine. Generated particles were small (<1 µm), passing from the machine through the patient and to the detector without coalescence with respiratory aerosol, thereby unlikely to carry viral particles. More aerosol was generated in cough from patients with COVID-19 (n=8) than volunteers.Conclusions: In healthy volunteers, standard non-humidified CPAP is associated with less aerosol emission than breathing, speaking or coughing. Aerosol emission from the respiratory tract does not appear to be increased by HFNO. Although direct comparisons are complex, cough appears to be the main aerosol-generating risk out of all measured activities. [ABSTRACT FROM AUTHOR]
Copyright of Thorax is the property of BMJ Publishing Group and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:00406376
DOI:10.1136/thoraxjnl-2021-217577