دورية أكاديمية

Influence of Staged-Air on Airflow, Combustion Characteristics and NOx Emissions of a Down-Fired Pulverized-Coal 300 MWe Utility Boiler with Direct Flow Split Burners.

التفاصيل البيبلوغرافية
العنوان: Influence of Staged-Air on Airflow, Combustion Characteristics and NOx Emissions of a Down-Fired Pulverized-Coal 300 MWe Utility Boiler with Direct Flow Split Burners.
المؤلفون: ZHENGQI LI1 green@hit.edu.cn, MIN KUANG1, JIA ZHANG1, YUNFENG HAN1, QUNYI ZHU1, LIANJIE YANG1, WEIGUANG KONG1
المصدر: Environmental Science & Technology. 2/1/2010, Vol. 44 Issue 3, p1130-1136. 7p.
مصطلحات موضوعية: *CHEMISTRY experiments, *COAL-fired furnaces, *AERODYNAMICS research, *AIR flow, *BOILER fuel, *PULVERIZED coal, *BOILER efficiency, *NITROGEN oxides & the environment, *AIR pollution measurement
مستخلص: Cold airflow experiments were conducted to investigate the aerodynamic field in a small-scale furnace of a down-fired pulverized-coal 300 MWe utility boiler arranged with direct flow split burners enriched by cyclones. By increasing the staged-air ratio, a deflected flow field appeared in the lower furnace; larger staged-air ratios produced larger deflections. Industrial-sized experiments on a full-scale boiler were also performed at different staged-air damper openings with measurements taken of gas temperatures in the burner region and near the right-side wall, wall heat fluxes, and gas components (O2, CO, and NOx) in the near-wall region. Combustion was unstable at staged-air damper openings below 30%. For openings of 30% and 40%, late ignition of the pulverized coal developed and large differences arose in gas temperatures and heat fluxes between the regions near the front and rear walls. In conjunction, carbon content in the fly ash was high and boiler efficiency was low with high NOx emission above 1200 mg/m³ (at 6% O2 dry). For fully open dampers, differences in gas temperatures and heat fluxes, carbon in fly ash and NOx emission decreased yielding an increase in boiler efficiency. The optimal setting is fully open staged-air dampers. [ABSTRACT FROM AUTHOR]
قاعدة البيانات: Academic Search Index
الوصف
تدمد:0013936X
DOI:10.1021/es903085v