دورية أكاديمية

Myocardial multilayer strain does not provide additional value for detection of myocardial viability assessed by SPECT imaging over and beyond standard strain.

التفاصيل البيبلوغرافية
العنوان: Myocardial multilayer strain does not provide additional value for detection of myocardial viability assessed by SPECT imaging over and beyond standard strain.
المؤلفون: Orloff, Elisabeth, Fournier, Pauline, Bouisset, Frédéric, Moine, Thomas, Cournot, Maxime, Elbaz, Meyer, Carrié, Didier, Galinier, Michel, Lairez, Olivier, Cognet, Thomas
المصدر: Echocardiography; Sep2018, Vol. 35 Issue 9, p1300-1309, 10p
مصطلحات موضوعية: MYOCARDIUM physiology, MYOCARDIUM, DIAGNOSTIC imaging, CARDIAC patients, SPECTROPHOTOMETRY, SINGLE-photon emission computed tomography, CORONARY angiography, ANATOMY
مستخلص: Background: The aim of this study was to evaluate the value of multilayer strain analysis to the assessment of myocardial viability (MV) through the comparison of both speckle tracking echocardiography and single‐photon emission computed tomography (SPECT) imaging. We also intended to determine which segmental longitudinal strain (LS) cutoff value would be optimal to discriminate viable myocardium. Methods: We included 47 patients (average age: 61 ± 11 years) referred to our cardiac imaging center for MV evaluation. All patients underwent transthoracic echocardiography with measures of LS, SPECT, and coronary angiography. Results: In all, 799 segments were analyzed. We correlated myocardial tracer uptake by SPECT with sub‐endocardial, sub‐epicardial, and mid‐segmental LS values with r = .514 P < .0001, r = .501 P < .0001, and r = .520 P < .0001, respectively. The measurements of each layer strain (sub‐endocardial, sub‐epicardial, and mid) had the same performance to predict MV viability as defined by SPECT with areas under curve of 0.819 [0.778–0.861, P < .0001], 0.809 [0.764–0.854, P < .0001], and 0.817 [0.773–0.860, P < .0001], respectively. The receiver‐operating characteristic analysis yielded a cutoff value of −6.5% for mid‐segmental LS with a sensitivity of 76% and specificity of 76% to predict segmental MV as defined by SPECT. Conclusions: Multilayer strain analysis does not evaluate MV with more accuracy than standard segmental LS analysis. [ABSTRACT FROM AUTHOR]
Copyright of Echocardiography is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:07422822
DOI:10.1111/echo.14022