دورية أكاديمية

Prospective evaluation of changes in anterior segment morphology after laser iridotomy in Chinese eyes by rotating Scheimpflug camera imaging.

التفاصيل البيبلوغرافية
العنوان: Prospective evaluation of changes in anterior segment morphology after laser iridotomy in Chinese eyes by rotating Scheimpflug camera imaging.
المؤلفون: Shuning Li, Hongtao Wang, Dapeng Mu, Jing Fu, Xiaozhen Wang, Jian Wang, Ningli Wang
المصدر: Clinical & Experimental Ophthalmology; Jan/Feb2010, Vol. 38 Issue 1, p10-14, 5p, 2 Color Photographs, 2 Charts
مصطلحات موضوعية: EYE diseases, MEDICAL lasers, OPHTHALMOLOGY, ANTERIOR chamber (Eye), PUPIL (Eye)
مستخلص: Background: To investigate the 3-D morphology changes of anterior segment in primary angle-closure suspect and primary angle-closure after laser peripheral iridotomy (LPI) using rotating Scheimpflug camera. Methods: A total of 37 eyes of 25 patients were enrolled in the study. Just before and after LPI, rotating Scheimpflug camera was performed on each selected eye by one skilled ophthalmologist. Comparison of anterior segment parameters before and after LPI such as central corneal thickness, central anterior chamber depth, peripheral anterior chamber depth, anterior chamber volume, pupil diameter and anterior chamber angle of cross-section photographs from 0° to 180° (ACA) were analysed. Results: Before and after LPI, central corneal thickness increased from 537.92 ± 27.92 µm to 541.49 ± 27.85 µm ( P = 0.074); no statistic changes of central anterior chamber depth were found before LPI (1.72 ± 0.27 mm) and after LPI (1.70 ± 0.24 mm) ( P = 0.337); peripheral anterior chamber depth deepen from 0.89 ± 0.26 to 1.14 ± 0.26 mm ( P = 0.000); anterior chamber volume increased from 55.54 ± 14.25 to 82.65 ± 17.63 mm3 ( P = 0.000); average pupil diameter of all patients are 1.72 ± 0.42 and 1.63 ± 0.46 mm, respectively, showed no statistic difference ( P = 0.228). ACA widen from 25.51 ± 5.66° to 28.11 ± 5.67° in 9 o'clock direction( P = 0.005), and from 25.77 ± 5.15° to 27.91 ± 4.87° in 3 o'clock direction after LPI ( P = 0.020). Conclusion: LPI induce dramatic changes of 3-D anterior segment morphology in primary angle-closure suspect and primary angle-closure. [ABSTRACT FROM AUTHOR]
Copyright of Clinical & Experimental Ophthalmology is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:14426404
DOI:10.1111/j.1442-9071.2010.02205.x