Continuous glucose monitoring-based time-in-range using insulin glargine 300 units/ml versus insulin degludec 100 units/ml in type 1 diabetes

التفاصيل البيبلوغرافية
العنوان: Continuous glucose monitoring-based time-in-range using insulin glargine 300 units/ml versus insulin degludec 100 units/ml in type 1 diabetes
المؤلفون: Battelino, Tadej, Danne, Thomas, Edelman, Steve V., Choudhary, Pratik, Renard, Eric, Westerbacka, Jukka, Mukherjee, Bhaswati, Pilorget, Valerie, Coudert, Mathieu, Bergenstal, Richard M.
المصدر: Diabetes, obesity & metabolism, vol. 25, no. 2, pp. 545-555, 2023.
بيانات النشر: Wiley, 2023.
سنة النشر: 2023
مصطلحات موضوعية: glycaemic control, bazalni inzulin, udc:616.379, type 1 diabetes, stalno spremljanje glukoze, insulin analogues, randomized trial, continuous glucose monitoring, basal insulin, sladkorna bolezen tipa 1, naključno preskušanje, nadzor glikemije, inzulinski analogi
الوصف: Aim: To use continuous glucose monitoring (CGM)-based time-in-range (TIR) as a primary efficacy endpoint to compare the second-generation basal insulin (BI) analogues insulin glargine 300 U/ml (Gla-300) and insulin degludec 100 U/ml (IDeg-100) in adults with type 1 diabetes (T1D). Materials and Methods: InRange was a 12-week, multicentre, randomized, active-controlled, parallel-group, open-label study comparing glucose TIR and variability between Gla-300 and IDeg-100 using blinded 20-day CGM profiles. The inclusion criteria consisted of adults with T1D treated with multiple daily injections, using BI once daily and rapid-acting insulin analogues for at least 1 year, with an HbA1c of 7% or higher and of 10% or less at screening. Results: Overall, 343 participants were randomized: 172 received Gla-300 and 171 IDeg-100. Non-inferiority (10% relative margin) of Gla-300 versus IDeg-100 was shown for the primary endpoint (percentage TIR ≥ 70 to ≤ 180 mg/dl): least squares (LS) mean (95% confidence interval) 52.74% (51.06%, 54.42%) for Gla-300 and 55.09% (53.34%, 56.84%) for IDeg-100 LS mean difference (non-inferiority): 3.16% (0.88%, 5.44%) (non-inferiority P = .0067). Non-inferiority was shown on glucose total coefficient of variation (main secondary endpoint): LS mean 39.91% (39.20%, 40.61%) and 41.22% (40.49%, 41.95%), respectively LS mean difference (non-inferiority) −5.44% (−6.50%, −4.38%) (non-inferiority P < .0001). Superiority of Gla-300 over IDeg-100 was not shown on TIR. Occurrences of self-measured and CGM-derived hypoglycaemia were comparable between treatment groups. Safety profiles were consistent with known profiles, with no unexpected findings. Conclusions: Using clinically relevant CGM metrics, InRange shows that Gla-300 is non-inferior to IDeg-100 in people with T1D, with comparable hypoglycaemia and safety profiles.
وصف الملف: application/pdf; text/url
اللغة: English
تدمد: 1463-1326
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=od______3505::847f7b8ca88a7dc4f593d86b37cbf582Test
https://hdl.handle.net/20.500.12556/RUL-144586Test
حقوق: OPEN
رقم الانضمام: edsair.od......3505..847f7b8ca88a7dc4f593d86b37cbf582
قاعدة البيانات: OpenAIRE