Fatal infection of coronary stent implantation

التفاصيل البيبلوغرافية
العنوان: Fatal infection of coronary stent implantation
المؤلفون: Emmanuel Martin, Hughes Georges, Claude Beuscart, Eric Decoulx, Alain Prat, Jerome Guilley, Olivier Leroy, Gilles Beaucaire
المصدر: Catheterization and Cardiovascular Diagnosis. 39:168-170
بيانات النشر: Wiley, 1996.
سنة النشر: 1996
مصطلحات موضوعية: Male, medicine.medical_specialty, medicine.medical_treatment, Bacteremia, Coronary Disease, Anterior Descending Coronary Artery, Coronary Angiography, medicine.disease_cause, Fatal Outcome, Internal medicine, Coronary stent, medicine, Humans, Endocarditis, Pseudomonas Infections, cardiovascular diseases, Angioplasty, Balloon, Coronary, Surgical repair, business.industry, Coronary Aneurysm, Stent, Middle Aged, equipment and supplies, medicine.disease, Anti-Bacterial Agents, Surgery, surgical procedures, operative, Superinfection, cardiovascular system, Cardiology, Drug Therapy, Combination, Stents, Cardiology and Cardiovascular Medicine, Complication, business
الوصف: Among systemic infections occurring after percutaneous transluminal coronary angioplasty (PTCA) and coronary stent implantation, septic cardiac complications are rare. We report a new case of infective aneurysm of the left anterior descending coronary artery (LAD) following stent implantation. Infective mitral endocarditis due to Pseudomonas aeruginosa occurring a few weeks after stenting led to search for stent infection. Coronary angiography revealed a saccular aneurysm of the LAD. Despite surgical repair, a fatal outcome resulted.
تدمد: 1097-0304
0098-6569
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::8bb119404f7164e0770a0ebe2e81cf44Test
https://doi.org/10.1002Test/(sici)1097-0304(199610)39:2<168::aid-ccd12>3.0.co;2-d
حقوق: CLOSED
رقم الانضمام: edsair.doi.dedup.....8bb119404f7164e0770a0ebe2e81cf44
قاعدة البيانات: OpenAIRE