دورية أكاديمية

Performance of intermittently scanned continuous glucose monitoring systems in people with type 1 diabetes: A pooled analysis

التفاصيل البيبلوغرافية
العنوان: Performance of intermittently scanned continuous glucose monitoring systems in people with type 1 diabetes: A pooled analysis
المؤلفون: Moser, Othmar, Sternad, Christoph, Eckstein, Max L., Szadkowska, Agnieszka, Michalak, Arkadiusz, Mader, Julia K., Ziko, Haris, Elsayed, Hesham, Aberer, Felix, Sola‐Gazagnes, Agnes, Larger, Etienne, Fadini, Gian Poalo, Bonora, Benedetta Maria, Bruttomesso, Daniela, Boscari, Federico, Freckmann, Guido, Pleus, Stefan, Christiansen, Sverre C., Sourij, Harald
بيانات النشر: Universität Ulm
سنة النشر: 2023
المجموعة: OPARU (OPen Access Repository of Ulm University)
مصطلحات موضوعية: continuous glucose monitoring (CGM), type 1 diabetes, DEXCOM G4 PLATINUM, PHYSICAL-EXERCISE, FREESTYLE LIBRE, ACCURACY, SENSOR, ADULTS, IMPACT, FLASH, DDC 610 / Medicine & health
الوصف: Aims To conduct a pooled analysis to assess the performance of intermittently scanned continuous glucose monitoring (isCGM) in association with the rate of change in sensor glucose in a cohort of children, adolescents, and adults with type 1 diabetes. Material and Methods In this pooled analysis, isCGM system accuracy was assessed depending on the rate of change in sensor glucose. Clinical studies that have been investigating isCGM accuracy against blood glucose, accompanied with collection time points were included in this analysis. isCGM performance was assessed by means of median absolute relative difference (MedARD), Parkes error grid (PEG) and Bland-Altman plot analyses. Results Twelve studies comprising 311 participants were included, with a total of 15 837 paired measurements. The overall MedARD (interquartile range) was 12.7% (5.9-23.5) and MedARD differed significantly based on the rate of change in glucose (P < 0.001). An absolute difference of −22 mg/dL (−1.2 mmol/L) (95% limits of agreement [LoA] 60 mg/dL (3.3 mmol/L), −103 mg/dL (−5.7 mmol/L)) was found when glucose was rapidly increasing (isCGM glucose minus reference blood glucose), while a −32 mg/dL (1.8 mmol/L) (95% LoA 116 mg/dL (6.4 mmol/L), −51 mg/dL (−2.8 mmol/L)) absolute difference was observed in periods of rapidly decreasing glucose. Conclusions The performance of isCGM was good when compared to reference blood glucose measurements. The rate of change in glucose for both increasing and decreasing glucose levels diminished isCGM performance, showing lower accuracy during high rates of glucose change. ; publishedVersion
نوع الوثيقة: article in journal/newspaper
وصف الملف: application/pdf
اللغة: English
العلاقة: https://dom-pubs.pericles-prod.literatumonline.com/action/downloadSupplement?doi=10.1111%2Fdom.14609&file=dom14609-sup-0001-AppendixS1.docxTest; https://dom-pubs.pericles-prod.literatumonline.com/action/downloadSupplement?doi=10.1111%2Fdom.14609&file=dom14609-sup-0002-AppendixS2.tifTest; https://dom-pubs.pericles-prod.literatumonline.com/action/downloadSupplement?doi=10.1111%2Fdom.14609&file=dom14609-sup-0003-AppendixS3.tifTest; http://dx.doi.org/10.18725/OPARU-50965Test; https://oparu.uni-ulm.de/xmlui/123456789/51041Test; http://nbn-resolving.de/urn:nbn:de:bsz:289-oparu-51041-9Test
DOI: 10.18725/OPARU-50965
الإتاحة: https://doi.org/10.18725/OPARU-50965Test
https://oparu.uni-ulm.de/xmlui/123456789/51041Test
http://nbn-resolving.de/urn:nbn:de:bsz:289-oparu-51041-9Test
حقوق: CC BY-NC 4.0 International ; https://creativecommons.org/licenses/by-nc/4.0Test/
رقم الانضمام: edsbas.57E0484B
قاعدة البيانات: BASE