دورية أكاديمية

Cecal Resection with Bipolar Sealing Devices in a Rat Model.

التفاصيل البيبلوغرافية
العنوان: Cecal Resection with Bipolar Sealing Devices in a Rat Model.
المؤلفون: Tagkalos, E., Heimann, A., Gaiser, T., Hirsch, D., Gockel, I., Lang, H., Jansen-Winkeln, B.
المصدر: Journal of Investigative Surgery; Jan2020, Vol. 33 Issue 1, p59-66, 8p
مصطلحات موضوعية: SEALING devices, STAPLERS (Surgery), BLOOD vessels, RATS, APPENDECTOMY, CECUM
مستخلص: Background: Bipolar sealing devices are routinely used to seal blood vessels. The aim of the study is to evaluate the feasibility and safety of colonic sealing with the use of the bipolar energy devices in rats as model for experimental appendectomy. Methods: Seventy-five male Wistar rats underwent a cecal resection with four different bipolar sealing devices or a linear stapler. The harvesting procedure was performed immediately or at postoperative day (POD) 7. The sealing front bursting pressure (BP) was measured in both groups. At POD7, the resection line was clinically examined and the hydroxyproline (HDP) levels were determined. Hematoxylin and Eosin (H&E) staining was used for histopathological evaluation of the sealing front as well. Results: There was no mortality and no insufficiency. The BPs between the bipolar sealing devices showed no statistical differences. The early phase of the seal (POD 0) provides a low BP with an 30.8% increase until POD 7. The BPs in the stapler group showed significant better values. The hydroxyproline levels did not differ statistically between the groups. Histopathologically, there were more signs of ischemic necrosis in the stapler group than in the sealing devices groups. Conclusion: The resection and sealing of the cecum as an experimental appendectomy model with the use of bipolar energy devices proved feasible and safe in rats. The different energy devices in this study produce comparable results. To justify clinical practice in humans, several studies on the underlying mechanisms of early stage wound healing are needed. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Investigative Surgery is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:08941939
DOI:10.1080/08941939.2018.1469698