دورية أكاديمية

Reliability of the chin tuck neck flexion test for assessing endurance of short neck flexors in healthy individuals.

التفاصيل البيبلوغرافية
العنوان: Reliability of the chin tuck neck flexion test for assessing endurance of short neck flexors in healthy individuals.
المؤلفون: Dimitriadis, Zacharias, Kapreli, Eleni, Strimpakos, Nikolaos, Oldham, Jacqueline
المصدر: Physiotherapy Theory & Practice; May2015, Vol. 31 Issue 4, p299-302, 4p, 2 Charts, 1 Graph
مصطلحات موضوعية: EXERCISE tests, ANALYSIS of variance, CONFIDENCE intervals, DISCRIMINANT analysis, RANGE of motion of joints, RESEARCH methodology, NECK muscles, PROBABILITY theory, PSYCHOMETRICS, RESEARCH evaluation, STATISTICAL sampling, STATISTICS, T-test (Statistics), DATA analysis, INTER-observer reliability, REPEATED measures design, RESEARCH methodology evaluation, DATA analysis software
مصطلحات جغرافية: GREECE
مستخلص: Objectives: The aim of the study was to examine of the intra-rater reliability of the chin tuck neck flexion (CTNF) test for assessing the endurance of neck flexors. Materials and methods: The study was performed at the Cardiorespiratory laboratory of the Physiotherapy Department, School of Health and Caring Professions, TEI Lamia, Greece. Twenty healthy volunteers (males/females: 9/11, age: 22.2 ± 1.7 y ears) with no known musculoskeletal, cardiovascular, pulmonary, neurological, or psychiatric disorder were recruited. The participants were positioned in a supine position and were asked to raise their head 2.5 cm above the plinth and to maintain this position for as long as possible without losing craniocervical or cervical flexion. This test was repeated three times with 5-min intervals between the trials. Results: The results showed that this test could discriminate between neck flexor endurance in men and women. However, although the test seems to be highly reliable (ICC: 0.81-0.88), it presents unsatisfactory standard error of measurement (SEM: 10.7-14.7 s) and smallest detectable differences (SDD: 80.5-110.9%). Furthermore, subgroup analysis showed the test seems to be more reliable for women (ICC: 0.93-0.94) than for men (ICC: 0.68-0.8), but the SEM and SDD values for them remain unsatisfactory (SEM: 4.4-5.3 s, SDD: 57.5-63.99%). Conclusions: Due to high reproducibility and discriminant validity, clinicians and researchers might want to consider using the CTNF test for the assessment of neck flexor endurance. However, they should seek alternative measurement tools when they want to avoid a large measurement error. [ABSTRACT FROM AUTHOR]
Copyright of Physiotherapy Theory & Practice is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:09593985
DOI:10.3109/09593985.2014.1002874