دورية أكاديمية

The histopathological diagnosis of atypical meningioma: glass slide versus whole slide imaging for grading assessment

التفاصيل البيبلوغرافية
العنوان: The histopathological diagnosis of atypical meningioma: glass slide versus whole slide imaging for grading assessment
المؤلفون: Ammendola, Serena, Bariani, Elena, Eccher, Albino, Capitanio, Arrigo, Ghimenton, Claudio, Pantanowitz, Liron, Parwani, Anil, Girolami, Ilaria, Scarpa, Aldo, Barresi, Valeria
بيانات النشر: Linköpings universitet, Avdelningen för neurobiologi
Linköpings universitet, Medicinska fakulteten
Klinisk patologi
Univ Verona, Italy
Univ & Hosp Trust Verona, Italy
Univ Michigan, MI 48109 USA
Ohio State Univ, OH 43210 USA
Cent Hosp Bolzano, Italy
Univ Verona, Italy; Univ & Hosp Trust Verona, Italy
Univ Verona, Italy; Polyclin GB Rossi, Italy
SPRINGER
سنة النشر: 2021
المجموعة: Linköping University Electronic Press (LiU E-Press)
مصطلحات موضوعية: Atypical meningioma, Whole slide imaging, Digital, Recurrence, Reproducibility, Urology and Nephrology, Urologi och njurmedicin
الوصف: Limited studies on whole slide imaging (WSI) in surgical neuropathology reported a perceived limitation in the recognition of mitoses. This study analyzed and compared the inter- and intra-observer concordance for atypical meningioma, using glass slides and WSI. Two neuropathologists and two residents assessed the histopathological features of 35 meningiomas-originally diagnosed as atypical-in a representative glass slide and corresponding WSI. For each histological parameter and final diagnosis, we calculated the inter- and intra-observer concordance in the two viewing modes and the predictive accuracy on recurrence. The concordance rates for atypical meningioma on glass slides and on WSI were 54% and 60% among four observers and 63% and 74% between two neuropathologists. The inter-observer agreement was higher using WSI than with glass slides for all parameters, with the exception of high mitotic index. For all histological features, we found median intra-observer concordance of >= 79% and similar predictive accuracy for recurrence between the two viewing modes. The higher concordance for atypical meningioma using WSI than with glass slides and the similar predictive accuracy for recurrence in the two modalities suggest that atypical meningioma may be safely diagnosed using WSI. ; Funding Agencies|Universita degli Studi di Verona. FUR 2019, University of Verona, Italy
نوع الوثيقة: article in journal/newspaper
وصف الملف: application/pdf
اللغة: English
العلاقة: Virchows Archiv, 0945-6317, 2021, 478, s. 747-756; http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-172503Test; PMID 33305338; ISI:000597987500001
DOI: 10.1007/s00428-020-02988-1
الإتاحة: https://doi.org/10.1007/s00428-020-02988-1Test
http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-172503Test
حقوق: info:eu-repo/semantics/openAccess
رقم الانضمام: edsbas.9F04357
قاعدة البيانات: BASE