دورية أكاديمية

Indicazioni per la quantificazione delle componenti monoclonali nel siero = Recommendations for the quantification of serum monoclonal components (MC)

التفاصيل البيبلوغرافية
العنوان: Indicazioni per la quantificazione delle componenti monoclonali nel siero = Recommendations for the quantification of serum monoclonal components (MC)
المؤلفون: Vernocchi A, Dolci A, Ceriotti F, Lippi G, Merlini G, Graziani MS, Caldini A, Mussap M, Natali P, Patelli G, Maoggi S, Righetti G, Lalli A
المساهمون: A. Vernocchi, A. Dolci, F. Ceriotti, G. Lippi, G. Merlini, M. Graziani, A. Caldini, M. Mussap, P. Natali, G. Patelli, S. Maoggi, G. Righetti, A. Lalli
بيانات النشر: Società Italiana di Biochimica Clinica e Biologia Molecolare Clinica (SIBioC)
سنة النشر: 2015
المجموعة: The University of Milan: Archivio Istituzionale della Ricerca (AIR)
مصطلحات موضوعية: Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
الوصف: The quantification of MC provides a surrogate for monitoring the size of the population of malignant cells in patients affected by plasma cell disease (PCD). Consequently, clinical and laboratory guidelines on diagnosis, risk stratification and monitoring of PCD recommend MC quantification as a key information for patient management. To do that, liquid phase immunochemical determination of IgG, IgA and IgM in serum should not be used, because of the inability of the technique to distinguish between monoclonal and polyclonal immunoglobulins. However, new available immunoassays specifically measuring free light chains, or the "so-called" Hevylite assay, may reliably quantify specific MC. As a general recommendation, MC should be quantified on agarose gel electrophoresis by scanning densitometry or from capillary zone electrophoresis readout only, provided that a high resolution electrophoresis is performed and a low concentration MC obscured by other proteins is not present. For integration of the MC peak on electrophoresis, perpendicular drop method is recommended. MC is a critical "analyte" as the potential analytical pitfalls (detection limit depending on the position of the MC and on the polyclonal background, poor linearity of scanning methods, precision performance) show. Thus, a comprehensive program of IQC of MC quantification should be implemented as well as an EQAS.
نوع الوثيقة: article in journal/newspaper
اللغة: Italian
العلاقة: info:eu-repo/semantics/altIdentifier/wos/WOS:000376561100006; volume:39; issue:3; firstpage:199; lastpage:207; numberofpages:9; journal:BIOCHIMICA CLINICA; http://hdl.handle.net/2434/702592Test; info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84943257786; https://www.sibioc.it/bc/numero/bcnum/152Test
الإتاحة: http://hdl.handle.net/2434/702592Test
https://www.sibioc.it/bc/numero/bcnum/152Test
حقوق: info:eu-repo/semantics/openAccess
رقم الانضمام: edsbas.9BB945C1
قاعدة البيانات: BASE