العنوان: Ground-based calibration and characterization of LaBr3-SiPM-based gamma-ray detector on GECAM satellite: 8–160 keV
المؤلفون: He, Jian-Jian, An, Zheng-Hua, Peng, Wen-Xi, Li, Xin-Qiao, Xiong, Shao-Lin, Zhang, Da-Li, Qiao, Rui, Guo, Dong-Ya, Cai, Ce, Chang, Zhi, Chen, Can, Chen, Gang, Du, Yuan-Yuan, Gao, Min, Gao, Rui, Gong, Ke, Hou, Dong-Jie, Li, Chao-Yang, Li, Gang, Li, Lu, Li, Mao-Shun, Li, Xiao-Bo, Li, Xu-Fang, Li, Yan-Guo, Liang, Xiao-Hua, Liu, Jia-Cong, Liu, Xiao-Jing, Liu, Ya-Qing, Lu, Hong, Ma, Xiang, Meng, Bin, Shi, Feng, Song, Li-Ming, Sun, Xi-Lei, Wang, Chen-Wei, Wang, Hui, Wang, Hui-Zhen, Wang, Jin-Zhou, Wang, Yu-Sa, Wen, Xing, Wen, Xiang-Yang, Xiao, Shuo, Xu, Yan-Bing, Xu, Yu-Peng, Xue, Wang-Chen, Yang, Jia-Wei, Yang, Sheng, Yi, Qi-Bin, Zhang, Cheng-Mo, Zhang, Chao-Yue
المساهمون: National Natural Science Foundation of China, Chinese Academy of Sciences
المصدر: Monthly Notices of the Royal Astronomical Society ; volume 525, issue 3, page 3399-3412 ; ISSN 0035-8711 1365-2966
بيانات النشر: Oxford University Press (OUP)
سنة النشر: 2023
الوصف: As the main detector of the Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor mission (GECAM), the calibration of the energy response and detection efficiency of the gamma-ray detector (GRD) is the main content of the ground-based calibration. This article mainly focuses on the calibration of the energy response and detection efficiency in the 8–160 keV with a refined measurement around the absorption edges of the lanthanum bromide crystal ($\rm {LaBr_3}$). The GRD performances for different crystal types, data acquisition modes, working modes, and incident positions are also analysed in detail. We show that the calibration campaign is comprehensive, the detector performance meets the flight requirements, and the calibration results generally agree with simulations as expected. The detector’s model was corrected by the ground-based calibration, which led to the establishment of the calibration data base.
نوع الوثيقة: article in journal/newspaper
اللغة: English
DOI: 10.1093/mnras/stad2439
الإتاحة: https://doi.org/10.1093/mnras/stad2439Test
https://academic.oup.com/mnras/article-pdf/525/3/3399/51403066/stad2439.pdfTest
حقوق: https://academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_modelTest
رقم الانضمام: edsbas.D5E28DB1
قاعدة البيانات: BASE