A Novel Method for Implementation of Frameless StereoEEG in Epilepsy Surgery

التفاصيل البيبلوغرافية
العنوان: A Novel Method for Implementation of Frameless StereoEEG in Epilepsy Surgery
المؤلفون: Nowell, Mark, Rodionov, Roman, Diehl, Beate, Wehner, Tim, Zombori, Gergely, Kinghorn, Jane, Ourselin, Sebastien, Duncan, John, Miserocchi, Anna, McEvoy, Andrew
المصدر: Neurosurgery
بيانات النشر: Neurosurgery, 2014.
سنة النشر: 2014
مصطلحات موضوعية: Adult, Male, Epilepsy, Adolescent, Operative Technique, Electroencephalography, StereoEEG, Middle Aged, Magnetic Resonance Imaging, Multimodal Imaging, Electrodes, Implanted, Cohort Studies, Young Adult, Treatment Outcome, Frameless stereotaxy, Humans, Female, Prospective Studies, Tomography, X-Ray Computed, Neuronavigation, Aged
الوصف: BACKGROUND: Stereoelectroencephalography (SEEG) is an invasive diagnostic procedure in epilepsy surgery that is usually implemented with frame-based methods. OBJECTIVE: To describe a new technique of frameless SEEG and report a prospective case series at a single center. METHODS: Image integration and planning of electrode trajectories were performed preoperatively on specialized software and exported to a Medtronic S7 StealthStation. Trajectories were implemented by frameless stereotaxy using percutaneous drilling and bolt insertion. RESULTS: Twenty-two patients went this technique, with the insertion of 187 intracerebral electrodes. Of 187 electrodes, 175 accurately reached their neurophysiological target, as measured by postoperative computed tomography reconstruction and multimodal image integration with preoperative magnetic resonance imaging. Four electrodes failed to hit their target due to extradural deflection, and 3 were subsequently resited satisfactorily. Eight electrodes were off target by a mean of 3.6 mm (range, 0.9-6.8 mm) due to a combination of errors in bolt trajectory implementation and bending of the electrode. There was 1 postoperative hemorrhage that was clinically asymptomatic and no postoperative infections. Sixteen patients were offered definitive cortical resections, and 6 patients were excluded from resective surgery. CONCLUSION: Frameless SEEG is a novel and safe method for implementing SEEG and is easily translated into clinical practice. ABBREVIATIONS: EA, accuracy of electrode delivery SEEG, stereoelectroencephalography
اللغة: English
تدمد: 1524-4040
0148-396X
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=pmid________::361fb72accab8c808c0166d916825635Test
http://europepmc.org/articles/PMC4224568Test
حقوق: OPEN
رقم الانضمام: edsair.pmid..........361fb72accab8c808c0166d916825635
قاعدة البيانات: OpenAIRE