Measuring Ascending Aortic Stiffness In Vivo in Mice Using Ultrasound

التفاصيل البيبلوغرافية
العنوان: Measuring Ascending Aortic Stiffness In Vivo in Mice Using Ultrasound
المؤلفون: Maggie Kuo, Jochen Steppan, Theodore P. Abraham, Mark Butlin, Lakshmi Santhanam, Viachaslau Barodka, Artin A. Shoukas, Alberto Avolio, Dan E. Berkowitz
المصدر: Journal of Visualized Experiments.
بيانات النشر: MyJove Corporation, 2014.
سنة النشر: 2014
مصطلحات موضوعية: medicine.medical_specialty, Aorta, General Immunology and Microbiology, Cardiac cycle, business.industry, General Chemical Engineering, General Neuroscience, Ultrasound, General Biochemistry, Genetics and Molecular Biology, Compliance (physiology), Blood pressure, medicine.artery, Internal medicine, Ascending aorta, cardiovascular system, medicine, Cardiology, Aortic stiffness, Sodium nitroprusside, business, medicine.drug
الوصف: We present a protocol for measuring in vivo aortic stiffness in mice using high-resolution ultrasound imaging. Aortic diameter is measured by ultrasound and aortic blood pressure is measured invasively with a solid-state pressure catheter. Blood pressure is raised then lowered incrementally by intravenous infusion of vasoactive drugs phenylephrine and sodium nitroprusside. Aortic diameter is measured for each pressure step to characterize the pressure-diameter relationship of the ascending aorta. Stiffness indices derived from the pressure-diameter relationship can be calculated from the data collected. Calculation of arterial compliance is described in this protocol. This technique can be used to investigate mechanisms underlying increased aortic stiffness associated with cardiovascular disease and aging. The technique produces a physiologically relevant measure of stiffness compared to ex vivo approaches because physiological influences on aortic stiffness are incorporated in the measurement. The primary limitation of this technique is the measurement error introduced from the movement of the aorta during the cardiac cycle. This motion can be compensated by adjusting the location of the probe with the aortic movement as well as making multiple measurements of the aortic pressure-diameter relationship and expanding the experimental group size.
تدمد: 1940-087X
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::0efaf2542e2125c74c67c402faa479acTest
https://doi.org/10.3791/52200Test
حقوق: OPEN
رقم الانضمام: edsair.doi.dedup.....0efaf2542e2125c74c67c402faa479ac