دورية أكاديمية

Finite Element Analysis of Glass Fiber-Reinforced Polymer-(GFRP) Reinforced Continuous Concrete Beams

التفاصيل البيبلوغرافية
العنوان: Finite Element Analysis of Glass Fiber-Reinforced Polymer-(GFRP) Reinforced Continuous Concrete Beams
المؤلفون: Hazem Ahmad, Amr Elnemr, Nazam Ali, Qudeer Hussain, Krisada Chaiyasarn, Panuwat Joyklad
المصدر: Polymers, Vol 13, Iss 24, p 4468 (2021)
بيانات النشر: MDPI AG, 2021.
سنة النشر: 2021
المجموعة: LCC:Organic chemistry
مصطلحات موضوعية: concrete, glass fiber-reinforced polymer, stirrups, continuous-beam, moment redistribution, shear capacity, Organic chemistry, QD241-441
الوصف: Fiber-reinforced concrete (FRC) is a competitive solution for the durability of reinforced structures. This paper aims to observe the moment redistribution behavior occurring due to flexural and shear loading in Glass Fiber-Reinforced Polymer- (GFRP) reinforced continuous concrete beams. A rectangular cross-section was adopted in this study with dimensions of 200 mm in width and 300 mm in depth with a constant shear span-to-depth ratio of 3. The reinforcement ratio for the top and bottom were equal at sagging and hogging moment regions. A finite element model was created using Analysis System (ANSYS) and validated with the existing experimental results in the literature review. Based on the literature review, the parametric study was conducted on twelve beam specimens to evaluate the influence of concrete compressive strength, transversal GFRP stirrups ratio, and longitudinal reinforcement ratio on the redistribution of the moment in beams. Several codes and guidelines adopted different analytical models. The Canadian Standards Association (CSA) S806 adopted the modified compression field theory in predicting the shear capacity of the simply supported beams. Recently, various researchers encountered several factors and modifications to account for concrete contribution, longitudinal, and transverse reinforcement. A comparison between the predicting shear capacity of the generated finite element model, the analytical model, and the existing data from the literature was performed. The generated finite element model showed a good agreement with the experimental results, while the beam specimens failed in shear after undergoing significant moment redistribution from hogging to sagging moment region. The moment distribution observed about 21.5% from FEM of beam specimen GN-1.2-0.48-d, while the experimental results achieved 24% at failure load. For high strength concrete presented in beam specimen GH-1.2-0.63-d, the result showed about 20.2% moment distribution, compared to that achieved experimentally of 23% at failure load.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2073-4360
العلاقة: https://www.mdpi.com/2073-4360/13/24/4468Test; https://doaj.org/toc/2073-4360Test
DOI: 10.3390/polym13244468
الوصول الحر: https://doaj.org/article/b732fc1a6c9846cca3445795eba018b4Test
رقم الانضمام: edsdoj.b732fc1a6c9846cca3445795eba018b4
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20734360
DOI:10.3390/polym13244468