Power Quality Enhancement in a Grid-Integrated Photovoltaic System Using Hybrid Techniques

التفاصيل البيبلوغرافية
العنوان: Power Quality Enhancement in a Grid-Integrated Photovoltaic System Using Hybrid Techniques
المؤلفون: Prasad Kumar Bandahalli Mallappa, Herminio Martinez Garcia, Guillermo Velasco Quesada
المصدر: Applied Sciences, Vol 11, Iss 21, p 10120 (2021)
بيانات النشر: MDPI AG, 2021.
سنة النشر: 2021
المجموعة: LCC:Technology
LCC:Engineering (General). Civil engineering (General)
LCC:Biology (General)
LCC:Physics
LCC:Chemistry
مصطلحات موضوعية: photovoltaic, maximum power point tracking, grey wolf optimization, binary particle swarm optimization, multilevel inverter, total harmonic distortion, Technology, Engineering (General). Civil engineering (General), TA1-2040, Biology (General), QH301-705.5, Physics, QC1-999, Chemistry, QD1-999
الوصف: In recent years, the photovoltaic (PV) system was designed to supply solar power through photovoltaic arrays. The PV generator exhibits nonlinear voltage–current characteristics and its maximum power point tracking (MPPT), which varies with temperature and radiation. In the event of non-uniform solar insolation, several multiple maximum power points (MPPs) appear in the power–voltage characteristic of the PV module. Thus, a hybrid combination of binary particle swarm optimization (BPSO) and grey wolf optimization (GWO) is proposed herein to handle multiple MPPs. This combination is nowhere found in the literature, so the author chose this hybrid technique; and the main advantage of the proposed method is its ability to predict the global MPP (GMPP) in a very short time and to maintain accurate performance, even under different environmental conditions. Moreover, a 31-level multilevel inverter (MLI) was designed with a lower blocking voltage process to reduce the complexity of the circuit design. The entire system was executed in the MATLAB platform to examine the performance of the PV system, which was shown to extract a maximum power of 92.930 kW. The simulation design clearly showed that the proposed method with a 31-level MLI achieved better results in terms of total harmonic distortion (THD) at 1.60%, which is less when compared to the existing genetic algorithm (GA) and artificial neural networks (ANNs).
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2076-3417
العلاقة: https://www.mdpi.com/2076-3417/11/21/10120Test; https://doaj.org/toc/2076-3417Test
DOI: 10.3390/app112110120
الوصول الحر: https://doaj.org/article/45901b31d71549b3a43ef39dc7a524b4Test
رقم الانضمام: edsdoj.45901b31d71549b3a43ef39dc7a524b4
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20763417
DOI:10.3390/app112110120