دورية أكاديمية

Effects of Medium Cut-Off Polyarylethersulfone and Polyvinylpyrrolidone Blend Membrane Dialyzers in Hemodialysis Patients: A Systematic Review and Meta-Analysis of Randomized Controlled Trials

التفاصيل البيبلوغرافية
العنوان: Effects of Medium Cut-Off Polyarylethersulfone and Polyvinylpyrrolidone Blend Membrane Dialyzers in Hemodialysis Patients: A Systematic Review and Meta-Analysis of Randomized Controlled Trials
المؤلفون: Yu-Hui Hung, Tai-Shuan Lai, Mohamed Belmouaz, Ya-Chun Tu, Chun-Fu Lai, Shuei-Liong Lin, Yung-Ming Chen
المصدر: Membranes, Vol 12, Iss 443, p 443 (2022)
بيانات النشر: MDPI AG
سنة النشر: 2022
المجموعة: Directory of Open Access Journals: DOAJ Articles
مصطلحات موضوعية: artificial kidney, albumin, dialysis membrane expanded hemodialysis, beta 2-microglobulin, high retention onset, membrane characterization molecular weight, Chemical technology, TP1-1185, Chemical engineering, TP155-156
الوصف: The use of medium cut-off (MCO) polyarylethersulfone and polyvinylpyrrolidone blend membrane is an emerging mode in hemodialysis. Recent studies have shown that MCO membranes exhibit a middle high molecular weight uremic toxin clearance superior to standard high flux hemodialysis. We conducted a systematic literature review and meta-analysis of randomized controlled trials to investigate whether MCO membranes efficiently increase the reduction ratio of middle molecules, and to explore the potential clinical applications of MCO membranes. We selected articles that compared beta 2-microglobulin (β2M), kappa free light chain (κFLC), lambda free light chain (λFLC), interleukin-6 (IL-6), and albumin levels among patients undergoing hemodialysis. Five randomized studies with 328 patients were included. The meta-analysis demonstrated a significantly higher reduction ratio of serum β2M ( p < 0.0001), κFLC ( p < 0.0001), and λFLC ( p = 0.02) in the MCO group. No significant difference was found in serum IL-6 levels after hemodialysis. Albumin loss was observed in the MCO group ( p = 0.04). In conclusion, this meta-analysis study demonstrated the MCO membranes’ superior ability to clear β2M, κFLC, and λFLC. Serum albumin loss is an issue and should be monitored. Further studies are expected to identify whether MCO membranes could significantly improve clinical outcomes and overall survival.
نوع الوثيقة: article in journal/newspaper
اللغة: English
تدمد: 2077-0375
العلاقة: https://www.mdpi.com/2077-0375/12/5/443Test; https://doaj.org/toc/2077-0375Test; https://doaj.org/article/3f6006aaf3a6470c9f505d48e170d3c3Test
DOI: 10.3390/membranes12050443
الإتاحة: https://doi.org/10.3390/membranes12050443Test
https://doaj.org/article/3f6006aaf3a6470c9f505d48e170d3c3Test
رقم الانضمام: edsbas.2DF4C9A5
قاعدة البيانات: BASE
الوصف
تدمد:20770375
DOI:10.3390/membranes12050443