Failure analysis and design improvement of a rotary vane actuator vane seal.

التفاصيل البيبلوغرافية
العنوان: Failure analysis and design improvement of a rotary vane actuator vane seal.
المؤلفون: Huan, Sun1 (AUTHOR), Liangxi, Xie1 (AUTHOR) 10830948@qq.com, Tian, Xie1 (AUTHOR), Panfeng, Wu1 (AUTHOR)
المصدر: Sealing Technology. Apr2019, Vol. 2019 Issue 4, p5-8. 4p.
مصطلحات موضوعية: *DESIGN failures, *FAILURE analysis, ACTUATORS, EXPERIMENTAL design
مستخلص: This article mainly analyses vane seal damage of a vane-type rotary vane actuator (RVA) and looks at ways of improving the design of the vane seal. In view of the phenomenon of vane seal breakage that occurred during the experiments described, it is suggested that there may be material spikes in the system's cylinder block, the interference of the O-ring seal is too large or parts of the design are imperfect. The work discussed in this article aims to improve the design according to the experimental results – providing a solution to the problem of vane seal damage. Ultimately, the objective is to provide a reference for the design of RVA vane seals. [ABSTRACT FROM AUTHOR]
Copyright of Sealing Technology is the property of Mark Allen Holdings Limited and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Business Source Index
الوصف
تدمد:13504789
DOI:10.1016/S1350-4789(19)30121-7