دورية أكاديمية

Prospective Clinical Feasibility Study for MRI-Only Brain Radiotherapy

التفاصيل البيبلوغرافية
العنوان: Prospective Clinical Feasibility Study for MRI-Only Brain Radiotherapy
المؤلفون: Minna Lerner, Joakim Medin, Christian Jamtheim Gustafsson, Sara Alkner, Lars E. Olsson
المصدر: Frontiers in Oncology, Vol 11 (2022)
بيانات النشر: Frontiers Media S.A., 2022.
سنة النشر: 2022
المجموعة: LCC:Neoplasms. Tumors. Oncology. Including cancer and carcinogens
مصطلحات موضوعية: MRI-only, implementation, brain, glioma, sCT, radiotherapy, Neoplasms. Tumors. Oncology. Including cancer and carcinogens, RC254-282
الوصف: ObjectivesMRI-only radiotherapy (RT) provides a workflow to decrease the geometric uncertainty introduced by the image registration process between MRI and CT data and to streamline the RT planning. Despite the recent availability of validated synthetic CT (sCT) methods for the head region, there are no clinical implementations reported for brain tumors. Based on a preceding validation study of sCT, this study aims to investigate MRI-only brain RT through a prospective clinical feasibility study with endpoints for dosimetry and patient setup.Material and MethodsTwenty-one glioma patients were included. MRI Dixon images were used to generate sCT images using a CE-marked deep learning-based software. RT treatment plans were generated based on MRI delineated anatomical structures and sCT for absorbed dose calculations. CT scans were acquired but strictly used for sCT quality assurance (QA). Prospective QA was performed prior to MRI-only treatment approval, comparing sCT and CT image characteristics and calculated dose distributions. Additional retrospective analysis of patient positioning and dose distribution gamma evaluation was performed.ResultsTwenty out of 21 patients were treated using the MRI-only workflow. A single patient was excluded due to an MRI artifact caused by a hemostatic substance injected near the target during surgery preceding radiotherapy. All other patients fulfilled the acceptance criteria. Dose deviations in target were within ±1% for all patients in the prospective analysis. Retrospective analysis yielded gamma pass rates (2%, 2 mm) above 99%. Patient positioning using CBCT images was within ± 1 mm for registrations with sCT compared to CT.ConclusionWe report a successful clinical study of MRI-only brain radiotherapy, conducted using both prospective and retrospective analysis. Synthetic CT images generated using the CE-marked deep learning-based software were clinically robust based on endpoints for dosimetry and patient positioning.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2234-943X
العلاقة: https://www.frontiersin.org/articles/10.3389/fonc.2021.812643/fullTest; https://doaj.org/toc/2234-943XTest
DOI: 10.3389/fonc.2021.812643
الوصول الحر: https://doaj.org/article/bcfde064f6b0467ab416835c2c5419b1Test
رقم الانضمام: edsdoj.bcfde064f6b0467ab416835c2c5419b1
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:2234943X
DOI:10.3389/fonc.2021.812643