دورية أكاديمية

Estimation of Diabetic Retinal Microaneurysm Perfusion Parameters Based on Computational Fluid Dynamics Modeling of Adaptive Optics Scanning Laser Ophthalmoscopy

التفاصيل البيبلوغرافية
العنوان: Estimation of Diabetic Retinal Microaneurysm Perfusion Parameters Based on Computational Fluid Dynamics Modeling of Adaptive Optics Scanning Laser Ophthalmoscopy
المؤلفون: Miguel O. Bernabeu, Yang Lu, Omar Abu-Qamar, Lloyd P. Aiello, Jennifer K. Sun
المصدر: Frontiers in Physiology, Vol 9 (2018)
بيانات النشر: Frontiers Media S.A., 2018.
سنة النشر: 2018
المجموعة: LCC:Physiology
مصطلحات موضوعية: diabetic retinopathy, microaneurysm, adaptive optics, blood flow, computational fluid dynamics, Physiology, QP1-981
الوصف: Diabetic retinopathy (DR) is a leading cause of vision loss worldwide. Microaneurysms (MAs), which are abnormal outpouchings of the retinal vessels, are early and hallmark lesions of DR. The presence and severity of MAs are utilized to determine overall DR severity. In addition, MAs can directly contribute to retinal neural pathology by leaking fluid into the surrounding retina, causing abnormal central retinal thickening and thereby frequently leading to vision loss. Vascular perfusion parameters such as shear rate (SR) or wall shear stress (WSS) have been linked to blood clotting and endothelial cell dysfunction, respectively in non-retinal vasculature. However, despite the importance of MAs as a key aspect of diabetic retinal pathology, much remains unknown as to how structural characteristics of individual MAs are associated with these perfusion attributes. MA structural information obtained on high resolution adaptive optics scanning laser ophthalmoscopy (AOSLO) was utilized to estimate perfusion parameters through Computational Fluid Dynamics (CFD) analysis of the AOSLO images. The HemeLB flow solver was used to simulate steady-state and time-dependent fluid flow using both commodity hospital-based and high performance computing resources, depending on the degree of detail required in the simulations. Our results indicate that WSS is lowest in MA regions furthest away from the feeding vessels. Furthermore, areas of low SR are associated with clot location in saccular MAs. These findings suggest that morphology and CFD estimation of perfusion parameters may be useful tools for determining the likelihood of clot presence in individual diabetic MAs.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1664-042X
العلاقة: https://www.frontiersin.org/article/10.3389/fphys.2018.00989/fullTest; https://doaj.org/toc/1664-042XTest
DOI: 10.3389/fphys.2018.00989
الوصول الحر: https://doaj.org/article/a1f0d9f4989d4931b29d7bf880b9219dTest
رقم الانضمام: edsdoj.1f0d9f4989d4931b29d7bf880b9219d
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:1664042X
DOI:10.3389/fphys.2018.00989