Routine Monitoring of Instrument Stability in a Milk Testing Laboratory With ASCA: A Pilot Study

التفاصيل البيبلوغرافية
العنوان: Routine Monitoring of Instrument Stability in a Milk Testing Laboratory With ASCA: A Pilot Study
المؤلفون: Nieuwoudt M. K., Giglio C., Marini F., Scott G., Holroyd S. E.
المساهمون: Nieuwoudt, M. K., Giglio, C., Marini, F., Scott, G., Holroyd, S. E.
بيانات النشر: Frontiers Media S.A.
سنة النشر: 2021
المجموعة: Sapienza Università di Roma: CINECA IRIS
مصطلحات موضوعية: analysis of variance with simultaneous component analysi, ASCA, FTIR spectroscopy, instrument stability, milk testing, quality control, standardization
الوصف: Mid-infrared spectroscopy has been developed as a reliable and rapid tool for routine analysis of fat, protein, lactose and other components in liquid milk. However, variations within and between FTIR instruments, even within the same milk testing laboratory, present a challenge to the accuracy of measurement of particularly minor components in the milk, such as individual fatty acids or proteins. In this study we have used Analysis of variance–Simultaneous Component Analysis (ASCA), to monitor the spectral variation between and within each of four different FOSS FTIR spectrometers over each week in an independent milk testing laboratory over 4years, between August 2017 and March 2021 (223weeks). On everyday of each week, spectra of the same pilot milk sample were recorded approximately every hour on each of the four instruments. Overall, variations between instruments had the largest effect on spectral variation over each week, making a significant contribution every week. Within each instrument, day-to-day variations over the week were also significant for all but two of the weeks measured, however it contributed less to the variance overall. At certain times other factors not explained by weekday variation or inter-instrument variation dominated the variance in the spectra. Examination of the scores and loadings of the weekly ASCA analysis allowed identification of changes in the spectral regions affected by drifts in each instrument over time. This was found to particularly affect some of the fatty acid predictions.
نوع الوثيقة: article in journal/newspaper
اللغة: English
العلاقة: info:eu-repo/semantics/altIdentifier/wos/WOS:000710801200001; volume:9; journal:FRONTIERS IN CHEMISTRY; https://hdl.handle.net/11573/1687626Test; info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85117456479
DOI: 10.3389/fchem.2021.733331
الإتاحة: https://doi.org/10.3389/fchem.2021.733331Test
https://hdl.handle.net/11573/1687626Test
رقم الانضمام: edsbas.66AAE840
قاعدة البيانات: BASE