No Effect of Periodic Continuous Glucose Monitoring on Hemoglobin A1c in Poorly Regulated Type 1 Patients

التفاصيل البيبلوغرافية
العنوان: No Effect of Periodic Continuous Glucose Monitoring on Hemoglobin A1c in Poorly Regulated Type 1 Patients
المؤلفون: Majbritt Kjelmann, Henrik U. Andersen, Minna Wittrup, Thomas Almdal
بيانات النشر: Diabetes Technology Society, 2013.
سنة النشر: 2013
مصطلحات موضوعية: Adult, Male, medicine.medical_specialty, Pediatrics, endocrine system diseases, Endocrinology, Diabetes and Metabolism, Biomedical Engineering, Dawn phenomenon, Bioengineering, law.invention, Young Adult, Randomized controlled trial, law, Diabetes mellitus, Blood Glucose Self-Monitoring, Internal Medicine, Clinical endpoint, Medicine, Humans, Hypoglycemic Agents, Insulin, Letters to the Editor, Glycemic, Aged, Aged, 80 and over, Glycated Hemoglobin, Type 1 diabetes, business.industry, nutritional and metabolic diseases, Middle Aged, medicine.disease, Crossover study, Surgery, Diabetes Mellitus, Type 1, Patient Satisfaction, Female, business
الوصف: The purpose of this study was to assess whether the use of periodic continuous glucose monitoring (CGM) lowers hemoglobin A1c (HbA1c) in poorly controlled type 1 diabetes patients. In a non-randomized study, patients with HbA1c >74 mmol/mol in three consecutive measurements were offered CGM for 6 days, then seen by a diabetologist and a diabetes nurse at start and again after 6 months. After 3 months, the patients were seen by a diabetes nurse and further offered to mail results of self-monitored blood glucose values (SMBG) for advice at 1.5 and 4.5 months. Patients who refused or were not offered CGM served as controls. Primary end point: HbA1c at 6 months. Secondary end point: Patient satisfaction evaluated by a semi-structured questionnaire.1 Forty-three (20 males/23 females) entered with only 35 completing the study. Thirteen patients had no diabetes complications, while 30 had either retinopathy or multiple complications. The median age was 49 (23–80) years and duration of diabetes was 18 (4–45) years. Intermittent CGM did not lower HbA1c (Table 1). Total insulin dose was 52 (12–120) IU at the start, and 54 (16–122) IU at 6 months (not significant). Seventy percent gained knowledge on their diabetes by using CGM. Seventy-five percent used the CGM frequently during the trial, but only 15% made many adjustments of insulin doses. Table 1 Results of HbA1c at Start and After Intervention with Periodic Continuous Glucose Monitoring in Poorly Regulated Type 1 Diabetes Patientsa A recent meta-analysis reports an overall mean difference in HbA1c for personal CGM versus SMBG of −0.30%.2 The effect of personal CGM requires that it is used often: for every 1 day increase of sensor use per week, the effect of CGM on HbA1c is increased by 0.15%.2 It is a general perception that periodic CGM may help identify problems not identified by SMBG, e.g., nocturnal hypoglycemia and dawn phenomenon. Whether it affects HbA1c is unclear. In adults, only one randomized study comparing periodic CGM to SMBG has been reported, and no difference in HbA1c was found 3 months after an intervention based on blinded CGM for 3 days. In children and adolescents, smaller nonrandomized studies suggest that unblinded periodic CGM results in a 0.2–0.4% decrease in HbA1c.3,4 The SWITCH study is a randomized, controlled, crossover study, with a 4-month washout period to evaluate if adding CGM to experienced pump patients with suboptimal metabolic control provides additional therapeutic benefit. Subjects were randomized to sensor on or sensor off arms for 6 months.5 In the intervention period, HbA1c was decreased 0.43% compared with patients not using CGM. Withdrawal of the sensor resulted in glycemic control reverting towards baseline levels during the washout period. Thus, our data and the available literature suggests that CGM is primarily useful as a tool for making real-time correction of diabetes treatment and that limited individual learning in relation to diabetes treatment can be gained from periodic use of CGM. In the present study, patient satisfaction with CGM was high. A recent meta-analysis also reports that users felt confident about the device and gave positive reviews.6
اللغة: English
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::7d4daf3034f71fb863456bcc94360f65Test
https://europepmc.org/articles/PMC3869151Test/
حقوق: OPEN
رقم الانضمام: edsair.doi.dedup.....7d4daf3034f71fb863456bcc94360f65