Validation and Establishment of a SARS-CoV-2 Lentivirus Surrogate Neutralization Assay as a pre-screening tool for the Plaque Reduction Neutralization Test

التفاصيل البيبلوغرافية
العنوان: Validation and Establishment of a SARS-CoV-2 Lentivirus Surrogate Neutralization Assay as a pre-screening tool for the Plaque Reduction Neutralization Test
المؤلفون: John Merluza, Johnny Ung, Kai Makowski, Alyssia Robinson, Kathy Manguiat, Nicole Mueller, Jonathan Audet, Julie Chih-Yu Chen, James E Strong, Heidi Wood, Alexander Bello
بيانات النشر: Cold Spring Harbor Laboratory, 2022.
سنة النشر: 2022
الوصف: Neutralization assays are important in understanding and quantifying neutralizing antibody responses towards SARS-CoV-2. The SARS-CoV-2 Lentivirus Surrogate Neutralization Assay (SCLSNA) can be used in biosafety level 2 (BSL-2) laboratories and has been shown to be a reliable, alternative approach to the plaque reduction neutralization test (PRNT). In this study, we optimized and validated the SCLSNA to assess its ability as a comparator and pre-screening method to support the PRNT. Comparability between the PRNT and SCLSNA was determined through clinical sensitivity and specificity evaluations. Clinical sensitivity and specificity produced acceptable results with 100% (95% CI: 94-100) specificity and 100% (95% CI: 94-100) sensitivity against ancestral Wuhan spike pseudotyped lentivirus. The sensitivity and specificity against B.1.1.7 spike pseudotyped lentivirus resulted in 88.3% (95% CI: 77.8 to 94.2) and 100% (95% CI: 94-100), respectively. Assay precision measuring intra-assay variability produced acceptable results for High (1:≥ 640 PRNT50), Mid (1:160 PRNT50) and Low (1:40 PRNT50) antibody titer concentration ranges based on the PRNT50, with %CV of 14.21, 12.47, and 13.28 respectively. Intermediate precision indicated acceptable ranges for the High and Mid concentrations, with %CV of 15.52 and 16.09, respectively. However, the Low concentration did not meet the acceptance criteria with a %CV of 26.42. Acceptable ranges were found in the robustness evaluation for both intra-assay and inter-assay variability. In summary, the validation parameters tested met the acceptance criteria, making the SCLSNA method fit for its intended purpose, which can be used to support the PRNT.
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_________::4cf9650b946908ff1a2c0967f3d72ab0Test
https://doi.org/10.1101/2022.09.13.507876Test
رقم الانضمام: edsair.doi...........4cf9650b946908ff1a2c0967f3d72ab0
قاعدة البيانات: OpenAIRE