دورية أكاديمية

A newly designed uncovered biliary stent for palliation of malignant obstruction: results of a prospective study.

التفاصيل البيبلوغرافية
العنوان: A newly designed uncovered biliary stent for palliation of malignant obstruction: results of a prospective study.
المؤلفون: Lawrence, Christopher, Nieto, Jose, Parsons, Willis G., Roy, André, Guda, Nalini M., Steinberg, Stephen E., Hasan, Muhammad K., Bucobo, Juan Carlos, Nagula, Satish, Dey, Nicholas D., Buscaglia, Jonathan M., Study Investigators
المصدر: BMC Gastroenterology; 6/10/2020, Vol. 20 Issue 1, p1-8, 8p, 1 Color Photograph, 1 Diagram, 2 Charts, 1 Graph
مصطلحات موضوعية: LONGITUDINAL method, INTERVAL analysis, MEDICAL schools, BILIARY tract, ADVERSE health care events
الشركة/الكيان: UNIVERSITY of Massachusetts Medical School
مستخلص: Background: Biliary decompression can reduce symptoms and improve quality of life in patients with malignant biliary obstruction. Endoscopically placed stents have become the standard of care for biliary drainage with the aim of improving hepatic function, relieving jaundice, and reducing adverse effects of obstruction. The purpose of this study was to evaluate the performance characteristics of a newly-designed, uncovered metal biliary stent for the palliation of malignant biliary obstruction.Methods: This post-market, prospective study included patients with biliary obstruction due to a malignant neoplasm treated with a single-type, commercially available uncovered self-expanding metal stent (SEMS). Stents were placed as clinically indicated for palliation of jaundice and to potentially facilitate neo-adjuvant chemotherapy. The main outcome measure was freedom from recurrent biliary obstruction (within the stent) requiring re-intervention within 1, 3, and 6 months of stent insertion. Secondary outcome measures included device-related adverse events and technical success of stent deployment.Results: SEMS were placed in 113 patients (73 men; mean age, 69); a single stent was inserted in 106 patients, and 2 stents were placed in 7 patients. Forty-eight patients survived and/or completed the 6 month study protocol. Freedom from symptomatic recurrent biliary obstruction requiring re-intervention was achieved in 108 of 113 patients (95.6, 95%CI = 90.0-98.6%) at study exit for each patient. Per interval analysis yielded the absence of recurrent biliary obstruction in 99.0% of patients at 1 month (n = 99; 95%CI = 97.0-100%), 96.6% of patients at 3 months (n = 77; 95%CI = 92.7-100%), and 93.3% of patients at 6 months (n = 48; 95%CI = 86.8-99.9%). In total, only 5 patients (4.4%) were considered failures of the primary endpoint. Most of these failures (4/5) were due to stent occlusion from tumor ingrowth or overgrowth. Overall technical success rate of stent deployment was 99.2%. There were 2 cases of stent-related adverse events (1.8%). There were no cases of post-procedure stent migration, stent-related perforation, or stent-related deaths.Conclusions: This newly designed and marketed biliary SEMS system appears to be effective at relieving biliary obstruction and preventing re-intervention within 6 months of insertion in the overwhelming majority of patients. The device has an excellent safety profile, and associated high technical success rate during deployment.Trial Registration: The study was registered on clinicaltrials.gov on 14 October 2013 and the study registration number is NCT01962168. University of Massachusetts Medical School did not participate in the study. [ABSTRACT FROM AUTHOR]
Copyright of BMC Gastroenterology is the property of BioMed Central and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:1471230X
DOI:10.1186/s12876-020-01325-9