التفاصيل البيبلوغرافية
العنوان: Automated Measurement of Microaneurysm Turnover
المؤلفون: John V. Forrester, Michael J. Cree, J. A. Olson, Peter F. Sharp, Keith A Goatman
المصدر: Investigative Opthalmology & Visual Science. 44:5335
بيانات النشر: Association for Research in Vision and Ophthalmology (ARVO), 2003.
سنة النشر: 2003
مصطلحات موضوعية: Adult, Male, Pathology, medicine.medical_specialty, Population, Diagnostic Techniques, Ophthalmological, Fundus (eye), Sensitivity and Specificity, Image Interpretation, Computer-Assisted, Humans, Medicine, Intraobserver Variation, Fluorescein Angiography, education, Reference standards, Aged, Observer Variation, Microaneurysm, education.field_of_study, Diabetic Retinopathy, Absolute number, medicine.diagnostic_test, business.industry, Retinal Vessels, Pattern recognition, Middle Aged, Reference Standards, Fluorescein angiography, Aneurysm, ROC Curve, Fluorescein angiogram, Female, Artificial intelligence, business
الوصف: An automated system for the measurement of microaneurysm (MA) turnover was developed and compared with manual measurement. The system analyses serial fluorescein angiogram (FA) or red-free (RF) fundus images; fluorescein angiography was used in this study because it is the more sensitive test for MAs. Previous studies have shown that the absolute number of MAs observed does not reflect the dynamic temporal nature of the MA population. In this study, almost half of the MAs present at baseline had regressed after a year and been replaced by new lesions elsewhere.Two clinical datasets were used to evaluate the performance of the automated turnover measurement system. The first consisted of 10 patients who had two fluorescein angiograms acquired a year apart. These data were analyzed, both manually and using the automated system, to investigate the inter- and intraobserver variations associated with manual measurement and to assess the performance of the automated system. The second dataset contained FAs from a further 25 patients. This dataset was analyzed only with the automated system to investigate some properties of microaneurysm turnover, in particular the differing detection sensitivities of new, static and regressed microaneurysms.Manual measurements exhibited large inter- and intraobserver variation. The sensitivity and specificity of the automated system were similar to those of the human observers. However, the automated measurements were more consistent-an important condition for accurate turnover quantification. Regressed MAs were more difficult to detect reliably than new MAs, which were themselves more difficult to detect reliably than static MAs.The automated system was shown to be fast, reliable, and repeatable, making it suitable for processing large numbers of images. Performance was similar to that of trained manual observers.
تدمد: 1552-5783
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::fc27522fa48c47e095b59dcbd3dcd553Test
https://doi.org/10.1167/iovs.02-0951Test
حقوق: OPEN
رقم الانضمام: edsair.doi.dedup.....fc27522fa48c47e095b59dcbd3dcd553
قاعدة البيانات: OpenAIRE