Evaluation of Platybasia with MR Imaging

التفاصيل البيبلوغرافية
العنوان: Evaluation of Platybasia with MR Imaging
المؤلفون: Koenigsberg, Robert A., Vakil, Nakul, Hong, Tom A., Htaik, Tun, Faerber, Eric, Maiorano, Tina, Dua, Monica, Faro, Scott, Gonzales, Carlos
المصدر: AJNR Am J Neuroradiol
بيانات النشر: American Society of Neuroradiology, 2005.
سنة النشر: 2005
مصطلحات موضوعية: Adult, Skull Base, Cephalometry, Image Enhancement, Magnetic Resonance Imaging, Sensitivity and Specificity, Cranial Fossa, Posterior, Platybasia, Image Processing, Computer-Assisted, Humans, Sella Turcica, Foramen Magnum, Child, Head and Neck, Retrospective Studies
الوصف: Platybasia, or abnormal obtuseness of the basal angle, was first measured on plain skull images. At present, evaluation of the brain and skull more commonly involves CT and MR imaging. We evaluated a new MR imaging method of evaluating platybasia.We retrospectively evaluated midline sagittal MR images in 200 adults and 50 children. The basal angle of the skull base was measured by using two methods: The standard MR imaging technique measured the angle formed by two lines-one joining the nasion and the center of the pituitary fossa connected by a line joining the anterior border of the foramen magnum and center of the pituitary fossa. The modified technique measured the angle formed by a line across the anterior cranial fossa and dorsum sellae connecting a line along the clivus.With the standard MR imaging technique, we obtained mean angles of 129 degrees +/- 6 degrees for adults and 127 degrees +/- 5 degrees for children, compared with 135.3 degrees (composite mean) in previous series. The modified technique produced values of 117 degrees +/- 6 degrees for adults and 114 degrees +/- 5 degrees for children, which were significantly lower that those of standard MR imaging and traditional radiography (P.05).Both the standard and modified MR imaging techniques produced basal angles lower than those previously reported with standard radiography. The modified technique uses clearly featured landmarks that can be reproduced consistently on midline sagittal T1 images. This technique and its corresponding values can be used as the new standard for evaluating the basal angle.
اللغة: English
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=pmid________::04dee660573d6c8e3095d9eb71669557Test
https://europepmc.org/articles/PMC7975016Test/
حقوق: OPEN
رقم الانضمام: edsair.pmid..........04dee660573d6c8e3095d9eb71669557
قاعدة البيانات: OpenAIRE