دورية أكاديمية

A silica long base tiltmeter with high stability and resolution

التفاصيل البيبلوغرافية
العنوان: A silica long base tiltmeter with high stability and resolution
المؤلفون: Boudin, F., Bernard, P., Longuevergne, Laurent, Florsch, Nicolas, Larmat, C., Courteille, C., Blum, P.-A., Vincent, T., Kammentaler, M.
المساهمون: Géosciences Montpellier, Université des Antilles et de la Guyane (UAG)-Institut national des sciences de l'Univers (INSU - CNRS)-Université de Montpellier (UM)-Centre National de la Recherche Scientifique (CNRS), Institut de Physique du Globe de Paris (IPGP), Institut national des sciences de l'Univers (INSU - CNRS)-Université Paris Diderot - Paris 7 (UPD7)-Université de La Réunion (UR)-Institut de Physique du Globe de Paris (IPG Paris)-Centre National de la Recherche Scientifique (CNRS), Structure et fonctionnement des systèmes hydriques continentaux (SISYPHE), Université Pierre et Marie Curie - Paris 6 (UPMC)-École Pratique des Hautes Études (EPHE), Université Paris Sciences et Lettres (PSL)-Université Paris Sciences et Lettres (PSL)-Mines Paris - PSL (École nationale supérieure des mines de Paris), Université Paris Sciences et Lettres (PSL)-Centre National de la Recherche Scientifique (CNRS), Los Alamos National Laboratory (LANL), Particulier, particulier
المصدر: ISSN: 0034-6748.
بيانات النشر: HAL CCSD
American Institute of Physics
سنة النشر: 2008
مصطلحات موضوعية: Sensors, remote sensing, Transducers, [SDU.ENVI]Sciences of the Universe [physics]/Continental interfaces, environment, [SDE.MCG]Environmental Sciences/Global Changes
الوصف: International audience ; In order to be able to provide valuable data in multiparameter measurement field operations, tiltmeters need to have a noise level better or equal than 10-9 rad for a period range from a few minutes to a few years and a long term stability ranging from 10-7 to 10-8 rad/yr. Tiltmeter measurements should also be as much as possible insensitive to thermal disturbances, by taking great care of the horizontality of the base line tube first. Secondly, thermal responses have been assessed. We also took great care of the coupling of our tiltmeters with the bedrock. We've designed a long base tiltmeter with sensors in silica which has a low dilatation coefficient. The linear variable displacement transducer is based on coil coupling (powered by an alternative voltage). Finally we show the results of two 100 m silica water tube tiltmeters which were installed in a mine in the French Vosges massif in the framework of a hydrology research project. These instruments show a remarkably good stability (6.5×10-9 rad/month) and a low noise level (of the order of 10-11 rad). Toroidal and spheroidal free modes of the Earth were observed after the two last major earthquakes on Sumatra.
نوع الوثيقة: article in journal/newspaper
اللغة: English
العلاقة: hal-00708013; https://hal.science/hal-00708013Test; https://hal.science/hal-00708013/documentTest; https://hal.science/hal-00708013/file/2008_RSI.pdfTest; BIBCODE: 2008RScI.79c4502B
DOI: 10.1063/1.2829989
الإتاحة: https://doi.org/10.1063/1.2829989Test
https://hal.science/hal-00708013Test
https://hal.science/hal-00708013/documentTest
https://hal.science/hal-00708013/file/2008_RSI.pdfTest
حقوق: info:eu-repo/semantics/OpenAccess
رقم الانضمام: edsbas.A032F6DB
قاعدة البيانات: BASE