دورية أكاديمية

Analyze of Ortho-SUV™, software base hybrid fixation on three planar femur deformity

التفاصيل البيبلوغرافية
العنوان: Analyze of Ortho-SUV™, software base hybrid fixation on three planar femur deformity
المؤلفون: Mohammadreza Effatparvar, Nima Jamshidi, Alireza Asghari Ardabili
المصدر: Tehran University Medical Journal, Vol 75, Iss 2, Pp 120-125 (2017)
بيانات النشر: Tehran University of Medical Sciences, 2017.
سنة النشر: 2017
المجموعة: LCC:Medicine (General)
مصطلحات موضوعية: deformity, external fixators, femur, foot deformities, Medicine (General), R5-920
الوصف: Background: Application of Hybrid 6 degrees of freedom fixation could lead to space motion in each 3 anatomic plates together and decrease the time of complex deformities correction. This study is an investigation on the function of hybrid external fixation and the influence of it on decreasing the treatment time. About this case utilize of Ortho-SUV Frame (OSF) system is explained for the first time in Iran and report of its novel. These robotic systems are divided into two groups: active and passive, about active system all movements are done by actuators in joints and links. And in passive, the system needs an operator or patient to actuates Sturats by hand. Methods: The femur bone has been investigated was non:union: with deformity in sagittal, frontal and transversal planes. Ilizarov external fixation was applicate firstly, with this condition that the OSF systems jacks were replaced instead of simple rods in side of fracture. Software work was done on February of 2016 in Ayatollah Taleghani Hospital, Tehran, Iran. Fractures were happened in a car accident and some other operating were perforemed for this patient without any result. Results: The correction of studied deformity needs 3 planar moving. Acting this movement by Ilizarov requirements 33 mm displacement in frontal plane, 12 mm horizontal distraction and 48 mm displacement in sagittal plane. Due to the rate of correction in Ilizarov which is 1 mm per day, this bone needs 93 days for general correction and three times changing in shape of rings connections. While, by using the hybrid external fixation, all displacements were corrected in 46 days and first connection had supported all planes. Conclusion: According to that the decreasing of treatment time is one of the main goal, the hybrid external fixation systems could be an appointment choice in complex deformities and replaced with some common fixation. In addition to, using of updated software increases the accuracy of displacement.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: Persian
تدمد: 1683-1764
1735-7322
العلاقة: http://tumj.tums.ac.ir/browse.php?a_code=A-10-25-5567&slc_lang=en&sid=1Test; https://doaj.org/toc/1683-1764Test; https://doaj.org/toc/1735-7322Test
الوصول الحر: https://doaj.org/article/b6c54d0d0e524f7096608160cea21fabTest
رقم الانضمام: edsdoj.b6c54d0d0e524f7096608160cea21fab
قاعدة البيانات: Directory of Open Access Journals