دورية أكاديمية

Evaluation of Minimally Invasive, Ultrasound-guided Synovial Biopsy Techniques by the OMERACT Filter - Determining Validation Requirements.

التفاصيل البيبلوغرافية
العنوان: Evaluation of Minimally Invasive, Ultrasound-guided Synovial Biopsy Techniques by the OMERACT Filter - Determining Validation Requirements.
المؤلفون: Humby, Frances, Kelly, Stephen, Bugatti, Serena, Manzo, Antonio, Filer, Andrew, Mahto, Arti, Fonseca, Joao Eurico, Lauwerys, Bernard, D'Agostino, Maria-Antonietta, Naredo, Esperanza, Lories, Rik, Montecucco, Carlomaurizio, Tak, Paul Peter, Fitzgerald, Oliver, Smith, Malcolm D, Veale, Douglas J, Choy, Ernest H, Strand, Vibeke, Pitzalis, Costantino
المساهمون: UCL - SSS/IREC/RUMA - Pôle de Pathologies rhumatismales, UCL - (SLuc) Service de rhumatologie
المصدر: Journal of Rheumatology, Vol. 43, no. 1, p. 208-213 (2016)
بيانات النشر: Journal of Rheumatology Publishing Co. Ltd.
سنة النشر: 2016
المجموعة: DIAL@UCL (Université catholique de Louvain)
مصطلحات موضوعية: Biopsy, Rheumatoid arthritis, Synovitis, Ultrasound
الوصف: OBJECTIVE: Because limited data currently support the clinical utility of peripherally expressed biomarkers in guiding treatment decisions for patients with rheumatoid arthritis, the search has turned to the disease tissue. The strategic aim of the Outcome Measures in Rheumatology (OMERACT) synovitis working group over the years has been to develop novel diagnostic and prognostic synovial biomarkers. A critical step in this process is to refine and validate minimally invasive, technically simple, robust techniques to sample synovial tissue, for use both in clinical trials and routine clinical practice. The objective of the synovitis working group (SWG) at OMERACT 12 (2014) was to examine whether recently developed ultrasound (US)-guided synovial biopsy techniques could be validated according to the OMERACT filter for future clinical use recommendation. METHODS: The SWG examined whether current data reporting US-guided synovial biopsy of both large and small joints addressed the OMERACT filters of truth, discrimination, and feasibility. RESULTS: There are currently limited data examining the performance of US-guided synovial biopsy, mainly from observational studies. Thus, it remains critical to evaluate its performance, within the clinical trials context, against the current gold standard of arthroscopic biopsy, with particular reference to: (1) synovial tissue yield, (2) capacity to determine treatment response as measured by a validated synovial biomarker, and (3) tolerability of the procedure. CONCLUSION: We summarize the discrete work packages agreed to as requirements to validate US-guided synovial biopsy and therefore lead to a global consensus on the use of synovial biopsy for research and clinical practice.
نوع الوثيقة: article in journal/newspaper
اللغة: Ndonga
تدمد: 0315-162X
1499-2752
العلاقة: boreal:172384; http://hdl.handle.net/2078.1/172384Test; info:pmid/26034155; urn:ISSN:0315-162X; urn:EISSN:1499-2752
DOI: 10.3899/jrheum.141199
الإتاحة: https://doi.org/10.3899/jrheum.141199Test
http://hdl.handle.net/2078.1/172384Test
حقوق: info:eu-repo/semantics/restrictedAccess
رقم الانضمام: edsbas.983F727E
قاعدة البيانات: BASE
الوصف
تدمد:0315162X
14992752
DOI:10.3899/jrheum.141199