MODELING TO IMPROVE THE PERFORMANCE OF REVERSE POWER RELAY IN GENERATOR
العنوان: | MODELING TO IMPROVE THE PERFORMANCE OF REVERSE POWER RELAY IN GENERATOR |
---|---|
المؤلفون: | Fahrul Rozi, Azriyenni Azhari Zakri |
المصدر: | Jurnal Ilmiah SINERGI, Vol 24, Iss 3, Pp 231-236 (2020) |
بيانات النشر: | Universitas Mercu Buana, 2020. |
سنة النشر: | 2020 |
مصطلحات موضوعية: | fault, Generator (computer programming), Computer science, generator, reverse power relay, modeling, AC power, Fault (power engineering), Interference (wave propagation), law.invention, Power (physics), Electricity generation, Relay, law, lcsh:TA1-2040, protective, lcsh:Engineering (General). Civil engineering (General), Reset (computing), Simulation |
الوصف: | The generator is the primary component in electricity generation and requires a protection system from internal and external interference that occurs. This study considers how to improve the performance of relays in power plants. A model of a generator that is executed in a fault condition to reset the protective equipment, namely Reverse Power Relay (RPR). The study is intended to model the state of internal and external fault on the generator by applying a working principle of RPR. The model is designed to anticipate the actual fault in the generator. The simulation results obtained output such as; active power, current and time delay relay. The RPR reset of the generator system is applied to the generator in Riau Power. The RPR is installed on the generator is -612 kW, equivalent to 30%, the relay delay time is 0.2 seconds. Based on standardization, the return of power reaches a maximum of -12.66 MW, which is captured 50% with a maximum replacement of 30 seconds. Results of the RPR simulation have been validated with the IEEE standard at a time delay that corresponds to the percentage of reverse power settings installed at 6% and a time delay of 0.6%. Finally, to maximize the protection system on the generator, adjust 50% to 95% of the installed settings. It can be said that the system is able to increase generator protection and minimize the impact of internal or external fault. |
اللغة: | Indonesian |
تدمد: | 2460-1217 1410-2331 |
الوصول الحر: | https://explore.openaire.eu/search/publication?articleId=doi_dedup___::9ab45ed556d5365edbe35bef3aef1532Test https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/7616Test |
حقوق: | OPEN |
رقم الانضمام: | edsair.doi.dedup.....9ab45ed556d5365edbe35bef3aef1532 |
قاعدة البيانات: | OpenAIRE |
تدمد: | 24601217 14102331 |
---|